Fluid Properties

  • ρ = m / V — density; ρ: density (kg/m³), m: mass (kg), V: volume (m³); applies to any continuum fluid.
  • μ = τ / (du/dy) — dynamic viscosity from Newton’s law of viscosity; μ: dynamic viscosity (Pa·s), τ: shear stress (Pa), du/dy: velocity gradient normal to shear (s⁻¹); Newtonian fluids in simple shear.
  • ν = μ / ρ — kinematic viscosity; ν: kinematic viscosity (m²/s), μ: dynamic viscosity (Pa·s), ρ: density (kg/m³); any fluid, often for momentum-diffusion scaling.
  • σ = F / L — surface tension; σ: surface tension (N/m), F: force along interface (N), L: length of contact line (m); liquid–gas or liquid–liquid interfaces.
  • SG = ρ_fluid / ρ_water — specific gravity; SG: dimensionless, ρ_fluid: fluid density (kg/m³), ρ_water ≈ 1000 (kg/m³ at 4 °C); ratio property.
  • γ = ρ g — specific weight; γ: specific weight (N/m³), ρ: density (kg/m³), g: gravity (9.81 m/s²); static fluids.
  • β = - (1/V) (dV/dp) and K = 1/β = - V (dp/dV) = ρ (dp/dρ) — compressibility β and bulk modulus K; β: (Pa⁻¹), K: (Pa), V: volume (m³), p: pressure (Pa), ρ: density (kg/m³); small elastic volume changes.
  • h_cap = 2 σ cosθ / (ρ g r) — capillary rise/depression in a tube; h_cap: height (m), σ: surface tension (N/m), θ: contact angle (rad), ρ: density (kg/m³), g: gravity (m/s²), r: tube radius (m); static wetting in small tubes, neglecting end effects.

Fluid Statics

  • P = ρ g h — hydrostatic pressure at depth below a free surface; P: pressure above surface pressure (Pa), ρ: fluid density (kg/m³), g: 9.81 (m/s²), h: vertical depth (m); constant-density fluid at rest.
  • ΔP = ρ g Δh — hydrostatic pressure difference for a positive downward depth change; ΔP: pressure change (Pa), ρ: density (kg/m³), g: (m/s²), Δh: vertical depth change (m); same fluid, hydrostatics (not Pascal’s law statement).
  • dp/dz = - ρ g — vertical pressure gradient; p: pressure (Pa), z: vertical coordinate positive upward (m); static fluid (any ρ(z)).
  • p_abs = p_atm + p_gauge — absolute vs gauge pressure; p_abs, p_atm, p_gauge: (Pa); pressure measurements.

Buoyancy and Stability

  • F_b = ρ_f V_d g — buoyant force; F_b: buoyant force (N), ρ_f: fluid density (kg/m³), V_d: displaced volume (m³), g: (m/s²); Archimedes’ principle.
  • GM = BM - BG — initial metacentric height; GM: (m), BM: distance from center of buoyancy to metacenter (m), BG: distance from buoyancy center to gravity center (m); small heel of floating bodies.
  • BM = I_waterplane / V_displaced — metacentric radius; I_waterplane: second moment of waterplane area about heel axis (m⁴), V_displaced: displaced volume (m³); small heel, floating body.
  • GM = KB + BM - KG — signed GM; KB: keel to center of buoyancy (m), KG: keel to center of gravity (m); small-angle initial stability, GM>0 stable, GM<0 unstable, GM=0 neutral.
  • M_righting ≈ W GM sinφ — restoring moment for small heel; M_righting: (N·m), W: weight = ρ_f g V_d for neutrally floating (N), φ: heel angle (rad), GM: (m); initial stability of floating bodies.

Fluid Kinematics

  • V = u i + v j + w k — velocity vector; V: velocity (m/s), u,v,w: components (m/s); 3D flow field.
  • a = (du/dt + u du/dx + v du/dy + w du/dz) i + … — material acceleration; a: acceleration (m/s²), u,v,w: velocities (m/s), spatial derivatives (1/s), time derivative (m/s²); general unsteady, nonuniform flows.
  • D(·)/Dt = ∂(·)/∂t + v · ∇(·) — material derivative; D/Dt: rate following fluid, v: velocity (m/s); Eulerian to Lagrangian link.
  • ω = ∇ × v — vorticity; ω: vorticity (1/s), v: velocity (m/s); rotation measure.
  • u = ∂ψ/∂y, v = -∂ψ/∂x — 2D incompressible stream function relations; ψ: stream function (m²/s), u,v: velocities (m/s); planar incompressible flow.
  • u = ∂φ/∂x, v = ∂φ/∂y and ∇²φ = 0 — potential flow; φ: velocity potential (m²/s), u,v: velocities (m/s); irrotational, incompressible flow.
  • dy/dx = v/u — streamline slope in 2D steady flow; u,v: velocity components (m/s); steady field lines.

Control Volume Analysis

  • ∂/∂t ∫_CV ρ dV + ∫_CS ρ (v · n) dA = 0 — continuity (integral); ρ: (kg/m³), v: (m/s), n: outward unit normal, dV: (m³), dA: (m²); any CV.
  • ∂/∂t ∫_CV ρ v dV + ∫_CS ρ v (v · n) dA = ΣF — linear momentum; v: (m/s), ΣF: sum of external forces (N); any CV, vector form; include pressure forces on CS and body forces/surfaces.
  • Q̇ - Ẇ_shaft = ṁ[(h_out - h_in) + (V_out² - V_in²)/2 + g(z_out - z_in)] — steady 1-inlet/1-outlet energy rate equation; Q̇: heat into CV (W), Ẇ_shaft: shaft work out (W), ṁ: mass flow rate (kg/s), h: specific enthalpy (J/kg), V: speed (m/s), z: elevation (m), g: (m/s²); steady, uniform sections; use kinetic-energy correction if needed.
  • ΣM_O = ∂/∂t ∫_CV (r × ρ v) dV + ∫_CS (r × ρ v)(v · n) dA — angular momentum (torque about O); M_O: torque (N·m), r: position vector (m); rotating-flow and turbomachinery analyses.

Continuity Equation

  • ∂ρ/∂t + ∇ · (ρ v) = 0 — differential continuity; ρ: density (kg/m³), v: velocity (m/s); general flows.
  • ∇ · v = 0 — incompressible differential continuity; v: velocity (m/s); constant ρ flows.
  • A₁ V₁ = A₂ V₂ — incompressible steady 1D; A: area (m²), V: average speed (m/s); single streamtube, constant ρ.
  • ρ₁ A₁ V₁ = ρ₂ A₂ V₂ — compressible steady 1D; ρ: density (kg/m³), A: (m²), V: (m/s); single streamtube.

Momentum Equation

  • F_avg = Δ(momentum_system)/Δt and ΣF = d(momentum_system)/dt — impulse–momentum; F: net external force (N), momentum: (kg·m/s), t: time (s); finite/infinite control mass.
  • ΣF = ρ Q (v_out - v_in) — compact steady 1-inlet/1-outlet momentum; ΣF: vector (N), ρ: (kg/m³), Q: volumetric flow (m³/s), v_out,v_in: average velocity vectors (m/s); steady, constant ρ, uniform profiles; include pressure forces at CS; use momentum-flux integrals for nonuniform.

Energy Equation

  • P1/(ρ g) + v1²/(2 g) + z1 = P2/(ρ g) + v2²/(2 g) + z2 + h_L — Bernoulli (head form with losses); P: pressure (Pa), ρ: (kg/m³), g: (m/s²), v: speed (m/s), z: elevation (m), h_L: head loss (m); steady incompressible flow, along a streamline, no pump/turbine, α≈1.
  • P1/(ρ g) + α1 v1²/(2 g) + z1 + h_p = P2/(ρ g) + α2 v2²/(2 g) + z2 + h_t + h_L — extended Bernoulli; α: kinetic-energy correction (–), h_p: pump head added (m), h_t: turbine head extracted (m); steady incompressible.
  • p₀ = p + ½ ρ v² — stagnation pressure (incompressible); p₀: (Pa), p: static pressure (Pa), ρ: (kg/m³), v: (m/s); subsonic, negligible compressibility.

Dimensional Analysis and Similitude

  • Π = dimensionless group from variables via Buckingham π — dimensional analysis; ensures similarity; choose repeating vars with independent dimensions.
  • Re = ρ V L / μ — Reynolds number; ρ: (kg/m³), V: speed (m/s), L: length (m), μ: (Pa·s); inertia/viscous ratio.
  • Fr = V / √(g L) — Froude number; g: (m/s²); gravity waves/free-surface similarity.
  • Ma = V / a — Mach number; a: speed of sound (m/s); compressibility.
  • We = ρ V² L / σ — Weber number; σ: surface tension (N/m); capillarity vs inertia.
  • Eu = Δp / (ρ V²) — Euler number; Δp: characteristic pressure drop (Pa); pressure–inertia scaling.
  • St = f L / V — Strouhal number; f: frequency (Hz); unsteadiness scaling.
  • Similarity requirements: match the dominant Π groups (e.g., Re for internal viscous flows; Re and Fr for free-surface; Ma for compressible; We for capillary-driven).

Internal Flow

  • Re = ρ v D / μ — Reynolds number in pipe; v: average speed (m/s), D: diameter (m); laminar if Re < 2300 (round pipe), turbulent if Re ≳ 4000.
  • D_h = 4 A / P — hydraulic diameter for noncircular ducts; D_h: (m), A: cross-sectional area (m²), P: wetted perimeter (m); internal flow correlations.
  • Δp = f (L/D) (ρ v²/2) — Darcy–Weisbach pressure drop; Δp: (Pa), f: Darcy friction factor (–), L: length (m), D: diameter (m), ρ: (kg/m³), v: (m/s); fully developed, steady, incompressible.
  • h_f = f (L/D) v²/(2 g) — head loss; h_f: (m), f: (–), v: (m/s), D: (m), g: (m/s²); same conditions.
  • f = 64 / Re — laminar Darcy friction factor; Re: (–); round pipes, fully developed laminar.
  • f = 0.3164 Re^(-0.25) — Blasius smooth-pipe correlation; 4×10³ ≲ Re ≲ 10⁵; turbulent, hydraulically smooth.
  • 1/√f = -2 log10[(ε/D)/3.7 + 2.51/(Re √f)] — Colebrook–White; ε: roughness height (m); turbulent, implicit f, commercial pipes.
  • h_m = K v²/(2 g) — minor loss head; h_m: (m), K: loss coefficient (–); fittings, entrances/exits.
  • Δp = 32 μ L V / D² — Hagen–Poiseuille (fully developed laminar); Δp: (Pa), μ: (Pa·s), L: (m), V: average speed (m/s), D: diameter (m); Newtonian, round tube, laminar.
  • L_e/D ≈ 0.05 Re — laminar entrance length; L_e: (m), D: (m), Re: (–); internal laminar pipe flow.

External Flow

  • F_D = ½ ρ V² C_D A — drag force; F_D: (N), ρ: (kg/m³), V: free-stream speed (m/s), C_D: drag coefficient (–), A: reference area (m²); bodies in crossflow.
  • F_L = ½ ρ V² C_L A — lift force; F_L: (N), C_L: lift coefficient (–); aerodynamic surfaces.
  • C_D,plate,avg ≈ 1.328 / √Re_L — average skin-friction coefficient (2τ_w,avg/(ρU²)) for laminar flat plate; Re_L = ρ U∞ L/μ; smooth plate, laminar to trailing edge.
  • c_f,x ≈ 0.664 / √Re_x — local laminar flat-plate skin friction; Re_x = ρ U∞ x/μ; zero pressure gradient.
  • C_f,avg ≈ 0.0592 / Re_L^(1/5) — average turbulent (from leading edge) smooth-plate skin friction; high Re, zero pressure gradient, hydraulically smooth.
  • Stokes drag: F_D = 3 π μ D V — creeping flow around sphere; μ: (Pa·s), D: sphere diameter (m), V: speed (m/s); Re ≪ 1.
  • V_t = ( (ρ_p - ρ_f) g D² ) / (18 μ ) — terminal velocity of small sphere (Stokes); ρ_p: particle density (kg/m³), ρ_f: fluid density (kg/m³); Re_t ≪ 1.

Boundary Layer Theory

  • δ(x) ≈ 5 x / √Re_x — laminar boundary-layer thickness on flat plate; δ: (m), x: distance from leading edge (m), Re_x: ρ U∞ x / μ; Blasius, zero pressure gradient.
  • δ*(x) = 1.7208 x / √Re_x — displacement thickness; δ*: (m); Blasius solution, ZPG.
  • θ(x) = 0.664 x / √Re_x — momentum thickness; θ: (m); Blasius, ZPG.
  • H = δ*/θ ≈ 2.59 — shape factor (laminar flat plate); H: (–); ZPG.
  • Re_x,cr ≈ 5 × 10^5 — typical transition criterion on smooth plate; Re_x: (–); approximate, depends on disturbance/roughness.
  • u⁺ = (1/κ) ln y⁺ + B — turbulent log-law of the wall; u⁺ = u/u_τ (–), y⁺ = y u_τ/ν (–), κ ≈ 0.41 (–), B ≈ 5.0 (–), u_τ = √(τ_w/ρ) (m/s); equilibrium turbulent boundary layer, inner region, smooth wall.

Flow Measurement

  • Q = C_d A₂ √( 2 Δp / (ρ (1 - β⁴)) ) — Venturi/orifice/nozzle meter discharge; Q: flow (m³/s), C_d: discharge coefficient (–), A₂: throat/orifice area (m²), Δp: upstream–throat differential (Pa), ρ: (kg/m³), β = d₂/d₁ (–); steady incompressible, single-phase, well-tapped meter.
  • V = C √( 2 Δp / ρ ) — Pitot tube velocity; V: local speed (m/s), C: Pitot coefficient (–), Δp: impact (stagnation–static) pressure (Pa), ρ: (kg/m³); subsonic incompressible.
  • Q = A √(2 g Δh) — ideal sharp-edged orifice under head; Q: (m³/s), A: orifice area (m²), g: (m/s²), Δh: head (m); add C_d for real flow: Q = C_d A √(2 g Δh).

Compressible Flow (Basics)

  • p₀/p = (1 + (γ - 1) M²/2)^(γ/(γ - 1)) — isentropic static-to-stagnation pressure; p₀: stagnation pressure (Pa), p: static (Pa), γ: ratio of specific heats (–), M: Mach (–); isentropic, calorically perfect gas.
  • T₀/T = 1 + (γ - 1) M²/2 — isentropic temperature; T₀: stagnation (K), T: static (K); same assumptions.
  • ρ₀/ρ = (1 + (γ - 1) M²/2)^(1/(γ - 1)) — isentropic density; ρ₀: stagnation (kg/m³), ρ: static (kg/m³).
  • A/A* = (1/M) [ (2/(γ + 1)) (1 + (γ - 1) M²/2) ]^((γ + 1)/(2(γ - 1))) — area–Mach relation; A*: sonic area; isentropic nozzle/duct.
  • ṁ = C_d A p₀ √(γ/(R T₀)) [ (2/(γ + 1))^((γ + 1)/(2(γ - 1))) ] — choked mass flow (M = 1 at throat); ṁ: (kg/s), A: throat area (m²), p₀: upstream stagnation (Pa), T₀: (K), R: specific gas constant (J/(kg·K)), C_d: (–); isentropic nozzle with sufficient pressure ratio.
  • M₂² = [1 + 0.5(γ - 1) M₁²] / [γ M₁² - 0.5(γ - 1)] — normal shock Mach relation; M₁,M₂: upstream/downstream Mach (–); adiabatic normal shock.
  • p₂/p₁ = 1 + 2 γ/(γ + 1) (M₁² - 1) — normal shock pressure ratio; p₂,p₁: downstream/upstream static pressures (Pa); normal shock.

Turbo Machinery

  • Δh₀ = U₂ V_{w2} - U₁ V_{w1} — Euler turbomachinery equation (specific total enthalpy change); Δh₀: (J/kg), U = r Ω blade speed (m/s), V_w: whirl (tangential) component (m/s); pump (Δh₀ > 0), turbine (Δh₀ < 0).
  • P = ρ Q (U₂ V_{w2} - U₁ V_{w1}) — shaft power (ideal); P: (W), ρ: (kg/m³), Q: volumetric flow (m³/s); steady, uniform sections.
  • H_p = (p₂/(ρ g) + V₂²/(2 g) + z₂) - (p₁/(ρ g) + V₁²/(2 g) + z₁) — pump head added; H_p: (m), p: (Pa), V: (m/s), z: (m), g: (m/s²); across pump between inlet 1 and outlet 2.
  • η_overall = (ρ g Q H_useful) / P_input — overall efficiency; η_overall: (–), H_useful: net head rise (m), P_input: shaft/electrical input (W); pumps/turbines accordingly.
  • η_h = g H / (U₂ V_{w2} - U₁ V_{w1}) — hydraulic efficiency; H: useful head (m); neglecting mechanical/volumetric losses.
  • η_v = Q_actual / Q_theoretical — volumetric efficiency; Q: (m³/s); leakage losses.
  • η_m = P_shaft_out / P_impeller — mechanical efficiency; P: power (W); mechanical losses.
  • NPSH_avail = (p_s/(ρ g)) + z_s - (p_v/(ρ g)) - h_{fs} — net positive suction head available; p_s: suction absolute pressure at pump centerline (Pa), z_s: suction elevation (m), p_v: vapor pressure (Pa), h_fs: suction line head loss (m); cavitation check for pumps.
  • σ_Thoma = NPSH_avail / H — cavitation parameter; σ_Thoma: (–), H: pump head rise (m); avoid cavitation: σ_Thoma ≥ σ_required.
  • Pump specific speed (rpm form): N_s,pump = N √Q / H^(3/4) — N: rotational speed (rpm), Q: flow (m³/s), H: head (m); pump selection/similarity.
  • Turbine specific speed (rpm form): N_s,turb = N √P / H^(5/4) — N: (rpm), P: power (W), H: head (m); turbine selection.
  • Affinity laws (geometrically similar): Q ∝ N D³, H ∝ N² D², P ∝ N³ D⁵ — Q: (m³/s), H: (m), P: (W), N: speed (1/s or rpm), D: impeller diameter (m); same fluid, similar operation.

Open Channel Flow

  • R = A / P — hydraulic radius; R: (m), A: flow area (m²), P: wetted perimeter (m); uniform open-channel sections.
  • V = C √(R S) — Chezy formula; V: mean velocity (m/s), C: Chezy coefficient (m¹/²/s), R: (m), S: energy slope (–); steady uniform flow.
  • V = (1/n) R^(2/3) S^(1/2) — Manning formula; n: Manning roughness (s/m^(1/3)); steady uniform flow.
  • Q = A V — discharge; Q: (m³/s), A: (m²), V: (m/s); any section.
  • E = y + V²/(2 g) — specific energy (per unit weight); E: (m), y: flow depth (m), V: mean velocity (m/s), g: (m/s²); rectangular channel; more generally use area and specific energy with q.
  • Fr = V / √(g y) — Froude number (rectangular); Fr: (–), V: (m/s), y: depth (m); critical flow at Fr = 1.
  • y_c = (q²/g)^(1/3) — critical depth, rectangular; y_c: (m), q = Q/b: discharge per unit width (m²/s), g: (m/s²), b: width (m); critical state.
  • y₂/y₁ = ½ [ √(1 + 8 Fr₁²) - 1 ] — hydraulic jump sequent-depth ratio (rectangular); y: depths (m), Fr₁: upstream Froude (–); horizontal, rectangular channel.
  • ΔE_jump = (y₂ - y₁)³ / (4 y₁ y₂) — energy loss in hydraulic jump; ΔE_jump: (m); rectangular, horizontal.

Fluid statics and manometry

  • Δp = ρ_m g Δh — simple U-tube manometer (same fluid both legs); Δp: pressure difference (Pa), ρ_m: manometer fluid density (kg/m³), g: (m/s²), Δh: column difference (m); static fluids.
  • General multi-fluid manometry: Σ (± ρ g Δz) = Δp — algebraic sum along vertical columns equals pressure difference; ρ: (kg/m³), Δz: signed vertical change (m); static columns with known interfaces.

Forces on submerged surfaces

  • F_R = ρ g A h̄ — resultant hydrostatic force on a plane surface; F_R: magnitude (N), A: area (m²), h̄: centroid depth below free surface (m); static, constant ρ.
  • h_cp = h̄ + I_G / (A h̄) — depth of center of pressure (plane surface); h_cp: (m), I_G: second moment about horizontal centroidal axis (m⁴); plane surface at any orientation, h̄ measured vertically.
  • Curved surfaces: F_H = ρ g A_v h̄_v, F_V = weight of imaginary fluid above surface — horizontal force equals force on vertical projection (A_v, h̄_v), vertical force equals weight of displaced column; static fluids.

Control-volume analysis: mass, momentum and energy

  • See “Control Volume Analysis,” “Continuity Equation,” “Momentum Equation,” and “Energy Equation” sections — same formulas apply; steady/unsteady as stated there.

Bernoulli’s equation and applications

  • V = √(2 g h) — Torricelli’s efflux (ideal jet from tank); V: jet speed (m/s), g: (m/s²), h: head above orifice centerline (m); large reservoir, negligible losses; real: V = √(2 g h) C_v.
  • p₀ - p = ½ ρ V² — Pitot dynamic pressure; see Flow Measurement for velocity extraction; incompressible.

Viscous flow and laminar flow in pipes

  • u(r) = u_max [1 - (r/R)²], u_max = 2 V — laminar parabolic profile; u(r): local speed (m/s), r: radius (m), R: pipe radius (m), V: average speed (m/s); fully developed laminar, circular tube.
  • Δp = 32 μ L V / D² and h_f = 32 ν L V / (g D²) — Hagen–Poiseuille relations; symbols as defined; Newtonian, laminar, fully developed.

Boundary layer

  • See “Boundary Layer Theory” section — thicknesses, skin friction, and transition criteria; external flow over smooth flat plates, zero pressure gradient.

Turbulent flow basics

  • f = 0.3164 Re^(-0.25) — Blasius (smooth pipe) correlation; 4×10³ ≲ Re ≲ 10⁵; fully turbulent, smooth.
  • 1/√f = -2 log10[(ε/D)/3.7 + 2.51/(Re √f)] — Colebrook–White; commercial pipes; use Moody chart for quick estimates.
  • u⁺ = (1/κ) ln y⁺ + B — wall log-law; κ ≈ 0.41, B ≈ 5.0; inner layer, equilibrium turbulence over smooth walls.

Flow through pipes and head losses

  • h_total = h_f + Σ h_m = f (L/D) v²/(2 g) + Σ K_i v²/(2 g) — total head loss; h_total: (m), h_f: friction (m), h_m: minor (m), K_i: loss coefficients (–); steady incompressible.
  • Series pipes: Δp_total = Σ Δp_i — pressure drops add; Δp: (Pa); same flow rate through each.
  • Parallel pipes: Q_total = Σ Q_i, h_f,i equal — flow rates add and head losses equal; Q: (m³/s), h_f: (m); common upstream/downstream nodes.

Basics of compressible flow

  • See “Compressible Flow (Basics)” — isentropic, area–Mach, choked flow, normal shock basics; perfect-gas assumptions as stated.

Impulse and reaction turbines

  • Pelton wheel jet power: P_jet = ½ ρ Q V_j² — P_jet: (W), Q: jet flow (m³/s), V_j: jet speed (m/s); impulse turbine feed.
  • Pelton force on deflected jet (ideal): F ≈ ρ Q (V_j - V_rel,out) along jet; F: (N); neglecting losses; use blade speed U and outlet relative velocity with deflection angle.
  • Degree of reaction: R = (Δp_static across rotor) / (ρ g H_stage) — R: (–), Δp_static: (Pa), H_stage: stage total head (m); reaction turbines (Francis/Kaplan).
  • Turbine efficiency: η_t = P_out / (ρ g Q H) — overall hydraulic-to-shaft; P_out: shaft power (W), H: available head (m); excludes mechanical/generator losses.
  • Unit quantities: N_u = N / √H, Q_u = Q / √H, P_u = P / H^(3/2) — scaling to H = 1 m; N: (rpm), Q: (m³/s), P: (W), H: (m); model–prototype similarity.

Centrifugal pumps

  • g H_e = U₂ V_{w2} - U₁ V_{w1} — Euler head for pump; H_e: Euler head (m), U,V_w as defined; ideal energy transfer.
  • H_m = (p_d/(ρ g) + V_d²/(2 g) + z_d) - (p_s/(ρ g) + V_s²/(2 g) + z_s) — manometric head; subscripts d: delivery, s: suction; includes velocity heads at nozzles if present.
  • P_input = (ρ g Q H_m) / η_overall — pump input power; P_input: (W), η_overall: (–); steady operation.
  • NPSH_avail = (p_s/(ρ g)) + z_s - (p_v/(ρ g)) - h_{fs} — cavitation margin at eye; symbols as above; avoid cavitation if NPSH_avail ≥ NPSH_req.
  • N_s,pump = N √Q / H^(3/4) — pump specific speed (rpm form); N: (rpm), Q: (m³/s), H: (m); selection/typology.
  • σ_slip = V_{w2,actual} / V_{w2,ideal} — slip factor; σ_slip: (–), V_{w2}: whirl at outlet (m/s); accounts for finite blade number.