Sensors and Transducers — formula sheet
Instrumentation Engineering · GATE IN · SI units. Drafted with Aria, checked by the AiCanCode.org team.
Static and Dynamic Characteristics of Sensors
S = Δq_o / Δq_i— Static sensitivity; Δq_o = output change (V, mA, Ω…), Δq_i = input change (°C, m, N…); linear region only.Error (% FS) = (measured − true) / full-scale span × 100— Accuracy quoted as % of full scale; for % of reading divide by the true value instead.Non-linearity (% FSO) = max deviation from reference line / full-scale output × 100— State the reference line (terminal, best-fit).Hysteresis (% FSO) = max (up − down) output difference / full-scale output × 100— From an up-and-down static calibration.q_o(t) = q_o(0) + K·Δq_i·(1 − e^(−t/τ))— First-order step response; τ = time constant (s), K = static gain; 63.2 % at t = τ, about 95 % at 3τ.M = 1 / √(1 + (ωτ)²),φ = −tan⁻¹(ωτ)— First-order sinusoidal amplitude ratio and phase; ω (rad/s).Mp = e^(−πζ/√(1 − ζ²)),ωd = ωn·√(1 − ζ²)— Second-order overshoot (fraction) and damped frequency; ζ < 1, ωn (rad/s).
Potentiometers and Strain Gauges
Vo = x·Vs / [1 + x(1 − x)·(Rp/Rm)]— Loaded potentiometer; x = wiper fraction (0–1), Vs (V), Rp = pot resistance (Ω), Rm = load (Ω); unloaded Vo = x·Vs.Resolution = 1/N— Wire-wound pot, fraction of full travel; N = number of turns.R = ρL/A— Resistance of a conductor; ρ (Ω·m), L (m), A (m²).GF = (ΔR/R)/ε = 1 + 2ν + (Δρ/ρ)/ε— Gauge factor; ε = strain (m/m), ν = Poisson's ratio; ≈ 2 for metal foil, 50–200 for semiconductor.ε = σ/E— Uniaxial elastic strain; σ (Pa), E (Pa).
Strain Gauge Bridges and Load Cells
Vo = Vex·[R1/(R1 + R2) − R4/(R3 + R4)]— General Wheatstone bridge output; Vex = excitation (V), R in Ω.Vo ≈ (Vex/4)·(ΔR1/R − ΔR2/R + ΔR3/R − ΔR4/R)— Small changes, equal arms: opposite arms add, adjacent arms subtract.Vo ≈ Vex·GF·ε/4(quarter),Vo = Vex·GF·ε/2(half, ±ε),Vo = Vex·GF·ε(full, ±ε) — Bridge configurations.Vo = Vex·x/(4 + 2x),x = GF·ε— Exact quarter-bridge output (shows non-linearity).Vo ≈ Vex·GF·ε·(1 + ν)/2— Column load cell with two axial and two transverse (Poisson) gauges.Vo = RO·Vex·F/F_rated— Load cell output; RO = rated output (V/V, e.g. 2 mV/V), F and F_rated (N).
Inductive Transducers and LVDT
L = N²/ℜ,ℜ = l_g/(μ0·A)— Self-inductance with air-gap-dominated reluctance; N = turns, l_g = total gap (m), A (m²), μ0 = 4π × 10⁻⁷ H/m.dL/L = −dg/g— Variable-gap sensitivity (non-linear, L ∝ 1/g).ΔL = L1 − L2 ≈ 2·L0·d/g— Differential (push–pull) pair; d = armature displacement (m).Vo = Vs1 − Vs2— LVDT secondaries in series opposition; zero (ideally) at null, phase reverses through null.Vo = S·Vex·x— LVDT linear range; S (V/V/mm), Vex (V rms), x (mm).
Capacitive Transducers
C = ε0·εr·A/d— Parallel plate; ε0 = 8.854 × 10⁻¹² F/m, εr (dimensionless), A (m²), d (m); fringing neglected.dC/C = −dd/d— Variable-gap sensitivity (non-linear); variable-area types are linear.C = 2π·ε0·εr·L / ln(b/a)— Coaxial electrodes; L (m), a = inner radius (m), b = outer radius (m).C(h) = 2π·ε0·[εr·h + (H − h)] / ln(b/a)— Coaxial level probe, non-conducting liquid; h = level (m), H = probe length (m).Vo = Vs·x/(2d)— Differential gap sensor in a bridge with two equal fixed arms; linear in x.X_C = 1/(2π·f·C)— Capacitive reactance (Ω).
Piezoelectric Transducers and Charge Amplifiers
Q = d·F— Charge; d = charge sensitivity (C/N, quartz ≈ 2.3 pC/N), F (N).V = Q/(Cp + Cc + Ca)— Voltage mode; crystal, cable and amplifier capacitances (F).g = d/(ε0·εr),V = g·t·p— Voltage sensitivity (V·m/N); t = thickness (m), p = pressure (Pa).Vo = −Q/Cf— Charge amplifier; Cf = feedback capacitance (F); independent of cable capacitance.τ = R·C,f_L = 1/(2πτ)— Low-frequency (high-pass) limit; R (Ω), C (F); no static response.
Hall Effect Sensors
V_H = I·B/(n·q·t) = R_H·I·B/t— Hall voltage; I (A), B (T, normal to plate), n = carrier density (m⁻³), q = 1.602 × 10⁻¹⁹ C, t = thickness along B (m).R_H = 1/(n·q)— Hall coefficient (m³/C); sign gives carrier type (negative for electrons).μ = R_H/ρ— Carrier mobility (m²/V·s); ρ = resistivity (Ω·m).B = μ0·N·I/l_g— Flux density in a gapped-core current sensor; l_g = gap (m).
Resistance Temperature Detectors
R_T = R0·(1 + α·T)— Linear model, 0–100 °C; R0 = resistance at 0 °C (Ω), α = 0.00385 /°C for IEC platinum, T (°C).R_T = R0·(1 + A·T + B·T²)— Callendar–Van Dusen, 0–850 °C; A = 3.9083 × 10⁻³ /°C, B = −5.775 × 10⁻⁷ /°C² (IEC 60751).ΔT_SH = I²·R_T/δ— Self-heating error; I (A), δ = dissipation constant (W/°C).T_err = R_lead/(α·R0)— 2-wire lead error (°C); R_lead = total lead resistance (Ω).
Thermistors
R_T = R0·exp[B·(1/T − 1/T0)]— NTC beta equation; B (K), T and T0 in kelvin.B = ln(R1/R2)/(1/T1 − 1/T2)— Beta from two calibration points.α = −B/T²— Local temperature coefficient (/K).1/T = A + B·ln R + C·(ln R)³— Steinhart–Hart equation; constants from three calibration points.
Thermocouples: Laws and Cold Junction Compensation
E ≈ S·(T_hot − T_ref)— Small-range approximation; S = mean Seebeck coefficient (V/°C, ≈ 41 µV/°C for type K).E(T, 0) = E(T, T_ref) + E(T_ref, 0)— Law of intermediate temperatures (cold-junction compensation): add emfs, then convert using reference tables.E_AB = E_AC + E_CB— Law of intermediate metals (corollary), same junction temperatures.E_pile = N·S·ΔT— Thermopile of N junction pairs.
Radiation Pyrometers
λ_max·T = 2.898 × 10⁻³ m·K— Wien's displacement law; λ_max (m), T (K).E = ε·σ·T⁴— Stefan–Boltzmann; σ = 5.67 × 10⁻⁸ W/m²·K⁴, ε = emissivity, T (K).T = Ta/ε^(1/4)— Total-radiation pyrometer emissivity correction; Ta = black-body reading (K).1/T = 1/Ta + (λ/C2)·ln ε— Spectral pyrometer (Wien approximation); C2 = 1.4388 × 10⁻² m·K, λ (m).
Photoelectric Sensors: Photodiodes, Phototransistors, LDRs
E = h·f = h·c/λ— Photon energy; h = 6.626 × 10⁻³⁴ J·s, c = 2.998 × 10⁸ m/s.λc = h·c/Eg ≈ 1.24/Eg— Cut-off wavelength (µm) for band gap Eg (eV); silicon ≈ 1.1 µm.I_p = η·q·P/(h·f) = R·P,R = η·q·λ/(h·c)— Photocurrent and responsivity (A/W); η = quantum efficiency, P (W).Vo = −I_p·Rf— Transimpedance amplifier; Rf (Ω).I_C ≈ (β + 1)·I_p— Phototransistor collector current.R = R1·(L/L1)^(−γ)— LDR; L = illuminance (lux), γ from datasheet (≈ 0.7–0.9).
Displacement, Velocity and Acceleration Measurement
Resolution = 360°/(4N)— Incremental encoder with ×4 quadrature decoding; N = pulses/rev.n = 60·f/N— Speed (rev/min) from pulse frequency f (Hz).e = B·l·v— Moving-coil velocity pickup; B (T), l (m), v (m/s).ωn = √(k/m)— Seismic natural frequency; k (N/m), m (kg).Z/(a/ωn²) = 1/√[(1 − r²)² + (2ζr)²]— Accelerometer amplitude ratio; r = ω/ωn ≪ 1, ζ ≈ 0.7 for flattest response.Z/Y = r²/√[(1 − r²)² + (2ζr)²]— Vibrometer amplitude ratio; → 1 for r ≫ 1.
Force, Torque and Vibration Measurement
τ_s = 16·T/(π·d³)— Surface shear stress of a solid shaft; T (N·m), d (m).ε_45 = ±τ_s/(2G),G = E/[2(1 + ν)]— Principal strains at ±45° for torque gauges; G (Pa).θ = T·L/(G·J),J = π·d⁴/32— Angle of twist (rad); L (m), J (m⁴).P = T·ω = 2π·n·T/60— Shaft power (W); n (rev/min).v = ω·x,a = ω²·x,rms = peak/√2— Sinusoidal vibration amplitudes.
Signal Conditioning Circuits for Sensors
G = (1 + 2R/RG)·(R3/R2)— Three-op-amp instrumentation amplifier gain.CMRR(dB) = 20·log10(Ad/Acm),V_err,out = Ad·Vcm/CMRR— Common-mode error; Vcm (V).fc = 1/(2π·R·C),|H| = 1/√(1 + (f/fc)²)— First-order RC low-pass.fs > 2·f_max— Sampling theorem (anti-aliasing).LSB = FSR/2ⁿ— ADC resolution; FSR (V), n = bits.I = 4 + 16·(x − x_min)/(x_max − x_min)— 4–20 mA transmitter current (mA).