Electrical Circuits

Electrical Circuits — formula sheet

Instrumentation Engineering · GATE IN · SI units. Drafted with Aria, checked by the AiCanCode.org team.

Circuit elements, Kirchhoff's laws and source transformation

  • v = R·i, v = L·di/dt, i = C·dv/dt — element laws; v in V, i in A, R in Ω, L in H, C in F, t in s.
  • Σ i_leaving = 0 — KCL at any node or closed surface (conservation of charge).
  • Σ v = 0 — KVL around any closed loop (conservation of energy).
  • R_eq = R1 + R2 + … — series resistors (same current).
  • 1/R_eq = 1/R1 + 1/R2 + … — parallel resistors (same voltage); two in parallel: R1·R2/(R1 + R2).
  • v1 = V·R1/(R1 + R2) — voltage divider; i1 = I·R2/(R1 + R2) — current divider.
  • Is = Vs/R — source transformation: Vs in series with R ≡ Is in parallel with the same R.
  • p = v·i — power absorbed (passive sign convention), W.
  • w_L = ½·L·i², w_C = ½·C·v² — stored energy, J.

Mesh and nodal analysis

  • I_jk = (Vj − Vk)/R — branch current from node voltages, A.
  • [G][V] = [I] — nodal equations; G_kk = sum of conductances at node k, G_jk = −(conductance between j and k), S.
  • [R][I] = [V] — mesh equations (planar circuits, clockwise meshes); R_jk = −(shared resistance), Ω.
  • n − 1 nodal equations; b − n + 1 mesh equations (n nodes, b branches).
  • Va − Vb = Vs — supernode constraint; Ij − Ik = Is — supermesh constraint.

Superposition, Thevenin and Norton theorems

  • x = Σ x_k — superposition (linear circuits): voltage sources shorted, current sources opened, dependent sources kept. Not valid for power.
  • Vth = Voc — Thevenin voltage = open-circuit voltage, V.
  • IN = Isc — Norton current = short-circuit current, A.
  • Rth = RN = Voc/Isc = Vt/It — Thevenin/Norton resistance (test-source method when dependent sources are present), Ω.
  • VL = Vth·RL/(Rth + RL) — load voltage; meter loading error Rth/(Rth + Rin).

Maximum power transfer and reciprocity theorems

  • RL = Rth — condition for maximum power to a resistive load (source fixed, load varied).
  • Pmax = Vth²/(4·Rth) — maximum power, W; efficiency w.r.t. the Thevenin source is 50%.
  • ZL = Zth* — AC conjugate match; Pmax = |Vth|²/(4·Rth) with Vth in RMS.
  • RL = |Zth| — best purely resistive load in AC.
  • I2/V1 = I1/V2 — reciprocity (linear bilateral networks, single source).

Star-delta transformation

  • R1 = R12·R31/(R12 + R23 + R31) — delta to star: star arm at terminal 1 = product of the two delta resistors touching terminal 1 / sum, Ω.
  • R12 = (R1·R2 + R2·R3 + R3·R1)/R3 — star to delta: delta resistor between 1 and 2 = sum of pairwise products / star arm at the opposite terminal, Ω.
  • RY = RΔ/3 — balanced case.
  • R_AC·R_DB = R_AD·R_CB — Wheatstone bridge balance (no current in the bridge arm).

Transient response of RL, RC and RLC circuits

  • x(t) = x(∞) + [x(0+) − x(∞)]·e^(−t/τ) — any first-order response.
  • τ = R·C, τ = L/R — time constants, s (R = Thevenin resistance seen by C or L after switching).
  • iL(0+) = iL(0−), vC(0+) = vC(0−) — continuity conditions.
  • α = R/(2L), ω0 = 1/√(LC), ζ = (R/2)·√(C/L) — series RLC; critical damping at R = 2√(L/C).
  • α = 1/(2RC), ζ = (1/(2R))·√(L/C) — parallel RLC.
  • ωd = ω0·√(1 − ζ²) — damped natural frequency (ζ < 1), rad/s.

Laplace transform analysis of circuits

  • F(s) = ∫₀⁻^∞ f(t)·e^(−st) dt — one-sided Laplace transform; s in s⁻¹.
  • u(t) → 1/s, e^(−at) → 1/(s + a), sin ωt → ω/(s² + ω²), cos ωt → s/(s² + ω²) — key pairs.
  • L{df/dt} = s·F(s) − f(0⁻) — differentiation property.
  • Z_L = sL with source L·i(0⁻); Z_C = 1/(sC) with source v(0⁻)/s — s-domain element models.
  • f(0⁺) = lim s→∞ s·F(s); f(∞) = lim s→0 s·F(s) — initial/final value theorems (FVT only if s·F(s) is stable).

Sinusoidal steady state, phasors and impedance

  • v(t) = Vm·cos(ωt + φ) ↔ V = Vm∠φ — phasor; V_rms = Vm/√2; ω = 2πf (rad/s).
  • Z_R = R, Z_L = jωL, Z_C = −j/(ωC) — element impedances, Ω.
  • Z = R + jX, |Z| = √(R² + X²), θ = tan⁻¹(X/R) — impedance; X > 0 inductive, X < 0 capacitive.
  • Y = 1/Z = G + jB, G = R/(R² + X²), B = −X/(R² + X²) — admittance, S.

Real, reactive and apparent power, power factor

  • P = V·I·cos θ = I²R — real power, W (V, I in RMS).
  • Q = V·I·sin θ = I²X — reactive power, var (positive for inductive loads).
  • |S| = V·I, S = V·I* = P + jQ — apparent (VA) and complex power.
  • pf = cos θ = P/|S| — power factor; state lagging or leading.
  • Qc = P·(tan θ1 − tan θ2), C = Qc/(ω·V²) — power-factor correction capacitor, F.

Series and parallel resonance, Q-factor and bandwidth

  • f0 = 1/(2π√(LC)) — resonant frequency, Hz (ω0 = 1/√(LC) rad/s).
  • Q = ω0L/R = (1/R)·√(L/C) — series RLC; BW = R/L rad/s; VL = VC = Q·V at resonance.
  • Q = R·√(C/L) = ω0RC — parallel RLC; BW = 1/(RC) rad/s.
  • BW = ω0/Q, ω0 = √(ω1·ω2) — bandwidth and half-power frequencies.
  • ω0 = √(1/(LC) − r²/L²), Rd = L/(C·r) — practical tank (coil resistance r).

Mutually coupled circuits and ideal transformer

  • v2 = M·di1/dt; k = M/√(L1·L2) — mutual inductance (H), coupling coefficient (0 ≤ k ≤ 1).
  • L = L1 + L2 ± 2M — series aiding (+) / opposing (−); M = (L_aid − L_opp)/4.
  • Zin = Z1 + (ωM)²/(Z2 + ZL) — reflected impedance of coupled coils.
  • V1/V2 = N1/N2, I1/I2 = N2/N1 — ideal transformer.
  • Zin = (N1/N2)²·ZL — impedance transformation; matching ratio N1/N2 = √(Rs/RL).

Balanced three-phase circuits and power measurement

  • VL = √3·Vph, IL = Iph — star; VL = Vph, IL = √3·Iph — delta.
  • P = √3·VL·IL·cos θ, Q = √3·VL·IL·sin θ, |S| = √3·VL·IL — θ = phase-impedance angle.
  • ZY = ZΔ/3 — delta to equivalent star impedance.
  • P = W1 + W2, tan θ = √3·(W2 − W1)/(W1 + W2) — two-wattmeter method; W1,2 = VL·IL·cos(30° ± θ) for a balanced load.

Two-port network parameters: Z, Y, h and ABCD

  • V1 = z11·I1 + z12·I2, V2 = z21·I1 + z22·I2 — Z (open-circuit) parameters, Ω.
  • I1 = y11·V1 + y12·V2, I2 = y21·V1 + y22·V2 — Y (short-circuit) parameters, S; [Y] = [Z]⁻¹.
  • V1 = h11·I1 + h12·V2, I2 = h21·I1 + h22·V2 — h (hybrid) parameters; h11 in Ω, h22 in S.
  • V1 = A·V2 − B·I2, I1 = C·V2 − D·I2 — ABCD (transmission) parameters, I2 entering port 2.
  • z12 = z21, y12 = y21, h12 = −h21, AD − BC = 1 — reciprocity.
  • z11 = z22, y11 = y22, A = D — symmetry.
  • Zin = z11 − z12·z21/(z22 + ZL) — input impedance of a terminated two-port.

Interconnection of two-port networks

  • [T] = [Ta]·[Tb] — cascade: ABCD matrices multiply in order.
  • [Z] = [Za] + [Zb] — series–series connection.
  • [Y] = [Ya] + [Yb] — parallel–parallel connection.
  • [h] = [ha] + [hb] — series–parallel; [g] = [ga] + [gb] — parallel–series (all need the port condition to hold).
  • [[1, Z], [0, 1]], [[1, 0], [Y, 1]] — ABCD of a series impedance and a shunt admittance.
  • Zin = (A·ZL + B)/(C·ZL + D) — input impedance of a terminated cascade.

Network functions, poles and zeros

  • H(s) = K·Π(s − z_i)/Π(s − p_j) — network function; zeros z_i, poles p_j.
  • |H(jω)| = K·Π|jω − z_i|/Π|jω − p_j|, ∠H = Σ∠(jω − z_i) − Σ∠(jω − p_j) — frequency response from pole-zero vectors.
  • Stable if all poles have negative real parts; simple jω-axis poles give marginal stability.
  • s² + 2ζω0·s + ω0² — standard second-order denominator.