Electrical Machines

Electrical Machines — formula sheet

Instrumentation Engineering · GATE IN · SI units. Drafted with Aria, checked by the AiCanCode.org team.

Magnetic Circuits and Electromechanical Energy Conversion

  • F = N·I — Magnetomotive force in ampere-turns (At); N turns, I current (A).
  • Φ = B·A — Flux (Wb); B flux density (T), A area (m²), uniform field.
  • B = μ0·μr·H ; μ0 = 4π × 10⁻⁷ H/m — flux density from field intensity H (A/m); valid below saturation.
  • R = l / (μ0·μr·A) ; Φ = F / ΣR — Reluctance (At/Wb) of a path of length l (m); series reluctances add.
  • L = N² / R = N·Φ / I — Inductance (H) of a linear magnetic circuit.
  • W = ½·L·I² ; w = B² / (2μ0) — Stored energy (J) and energy density in air (J/m³).
  • F_pull = B²·A / (2μ0) — Force (N) on one pole face of area A (m²) across an air gap.
  • T = ½·I²·dL/dθ — Reluctance torque (N·m), linear system, constant current.
  • e = B·l·v ; F = B·I·l — Motional EMF (V) and force on a conductor (N); B, l, v mutually perpendicular.

Single-phase Transformer: Construction and Equivalent Circuit

  • E = 4.44·f·N·Φm — rms induced EMF (V); f (Hz), N turns, Φm peak flux (Wb).
  • a = N1/N2 = E1/E2 ≈ V1/V2 = I2/I1 — Turns ratio; currents are in inverse ratio of turns.
  • Z' = a²·Z — Impedance referred from secondary to primary (Ω).
  • R01 = R1 + a²·R2 ; X01 = X1 + a²·X2 — Equivalent resistance and reactance referred to primary (Ω); divide by a² to refer to secondary.
  • I0 = √(Iw² + Iμ²) ; Iw = I0·cos φ0 ; Iμ = I0·sin φ0 — No-load current and its core-loss and magnetising components (A).

Transformer Phasor Diagram, Regulation and Efficiency

  • ε ≈ %R·cos φ ± %X·sin φ — Percent regulation; + lagging, − leading; %R = I·R02/V2 × 100, %X = I·X02/V2 × 100.
  • Regulation = (V20 − V2) / V2 × 100 % — Definition with full-load (rated) voltage V2 as base.
  • ε_max = %Z at cos φ = R/Z (lagging) ; ε = 0 at cos φ = X/Z (leading).
  • η = x·S·cos φ / (x·S·cos φ + Pi + x²·Pcu,FL) — Efficiency at fraction x of rated S (VA); Pi core loss, Pcu,FL full-load copper loss (W).
  • x_ηmax = √(Pi / Pcu,FL) — Load fraction at maximum efficiency (copper loss = core loss).
  • η_all-day = output energy (24 h) / input energy (24 h).

Open-circuit and Short-circuit Tests

  • cos φ0 = W0 / (V0·I0) ; R0 = V0/Iw ; X0 = V0/Iμ — OC test (usually LV side, rated voltage); W0 = core loss.
  • Z01 = Vsc/Isc ; R01 = Wsc/Isc² ; X01 = √(Z01² − R01²) — SC test (usually HV side, rated current); Wsc = copper loss at Isc.
  • Pcu,FL = Wsc·(I_rated / Isc)² — Full-load copper loss from an SC test at a different current.

Autotransformer and Instrument Transformers

  • k = V_LV / V_HV — Autotransformer ratio (< 1).
  • I_common = I_LV − I_HV — Current in the common winding (A).
  • S_conductive = k·S ; S_inductive = (1 − k)·S — Power transferred conductively and inductively (step-down, S = load VA).
  • Cu_auto / Cu_2-winding = 1 − k — Copper saving = k.
  • S_auto = S_2w·(V_HV / V_series) — Rating when a two-winding transformer is reconnected as an autotransformer.
  • Ratio error = (Kn·Is − Ip) / Ip × 100 % — CT (PT similarly with voltages); Kn = nominal ratio, e.g. 200/5.

DC Generator: Construction, EMF Equation and Characteristics

  • E = P·Φ·Z·N / (60·A) — Generated EMF (V); P poles, Φ flux per pole (Wb), Z armature conductors, N (rpm), A parallel paths (A = P lap, A = 2 wave).
  • E = V + Ia·Ra + V_brush — Generator voltage equation.
  • Ia = IL + Ish ; Ish = V / Rsh — Shunt generator currents (A).
  • E ∝ Φ·N — Same machine at two operating points.

DC Motor: Torque Equation, Characteristics and Starting

  • V = Eb + Ia·Ra — Motor voltage equation; Eb back EMF (V).
  • T = Ka·Φ·Ia ; Ka = P·Z / (2π·A) — Electromagnetic torque (N·m).
  • T = Eb·Ia / ω = 9.55·Eb·Ia / N — Torque from developed power; ω (rad/s), N (rpm).
  • Shunt: T ∝ Ia ; Series (unsaturated): T ∝ Ia², N ∝ Eb / Ia.
  • R_start = V / I_start − Ra — External starting resistance (Ω).

Speed Control of DC Motors

  • N ∝ (V − Ia·Ra) / Φ — Speed equation.
  • N2/N1 = [(V2 − Ia2·Ra) / (V1 − Ia1·Ra)]·(Φ1/Φ2) — Ratio between two operating points.
  • Ia2 = Ia1·(Φ1/Φ2) — Armature current after a flux change at constant load torque.
  • Armature voltage control: constant torque (below base speed) ; field control: constant power (above base speed).

Three-phase Induction Motor: Principle and Equivalent Circuit

  • Ns = 120·f / P ; s = (Ns − N) / Ns — Synchronous speed (rpm) and slip.
  • f2 = s·f ; E2s = s·E2 ; X2s = s·X2 — Rotor frequency (Hz), EMF and reactance at slip s.
  • I2 = E2 / √((R2/s)² + X2²) — Rotor current per phase (A).
  • Pag : Pcu2 : Pm = 1 : s : (1 − s) — Air-gap power, rotor copper loss, gross mechanical power.
  • T = Pag / ωs = Pm / ωr — Electromagnetic torque (N·m); ωs = 2π·Ns/60.

Torque-slip Characteristics of Induction Motors

  • T = 3·V1²·(R2'/s) / {ωs·[(R1 + R2'/s)² + X²]} — Torque (N·m); V1 per-phase voltage, X = X1 + X2'.
  • T ∝ s·E2²·R2 / (R2² + (s·X2)²) — Rotor-side form (stator impedance neglected).
  • s_m = R2' / √(R1² + X²) ≈ R2' / X — Slip at maximum torque.
  • Tmax = 3·V1² / (2·ωs·X) — Maximum torque (R1 neglected); independent of R2.
  • T / Tmax = 2·s·s_m / (s² + s_m²) ; Tst / Tmax = 2·s_m / (1 + s_m²) — Kloss relations (R1 neglected).
  • T ∝ V1² at a given slip.

Starting and Speed Control of Induction Motors

  • Tst / Tfl = (Ist / Ifl)²·sfl — Starting-to-full-load torque ratio.
  • Star–delta: I_line and Tst = 1/3 of DOL values.
  • Autotransformer (tap x): I_motor = x·Isc ; I_line = x²·Isc ; Tst = x²·Tst,DOL.
  • N = (120·f / P)·(1 − s) — Speed; control via f (with V/f constant), P (pole changing) or s (rotor resistance, voltage).
  • Low slip, constant torque: s ∝ R2 ; s ∝ 1/V².

Single-phase Induction Motors

  • s_f = s ; s_b = 2 − s — Slip with respect to forward and backward fields.
  • f_rotor,b = (2 − s)·f — Rotor frequency due to the backward field (Hz).
  • T = (Pf − Pb) / ωs — Net torque from forward and backward air-gap powers (N·m).

Stepper Motors and Servo Motors

  • θs = 360° / (m·Nr) = 360°·(Ns − Nr) / (Ns·Nr) — VR stepper step angle; m phases, Nr rotor teeth, Ns stator teeth.
  • θs = 360° / (2·m·Nr) — Hybrid stepper full-step angle (e.g. 2 phases, 50 teeth → 1.8°).
  • N = 60·f·θs / 360° — Speed (rpm) at pulse rate f (pulses/s).
  • ω(s)/Va(s) = K / (1 + τm·s) ; K = Kt/(Ra·B + Kt·Kb) ; τm = Ra·J/(Ra·B + Kt·Kb) — Armature-controlled DC servo (La neglected).

Synchronous Machines: Basic Principle and Applications

  • Ns = 120·f / P — Synchronous speed (rpm).
  • Eph = 4.44·f·Φ·Tph·kw — EMF per phase (V); Tph turns per phase, kw winding factor.
  • E = V + I·(Ra + j·Xs) — Generator phasor equation per phase (motor: V = E + I·(Ra + j·Xs)).
  • P = 3·V·E·sin δ / Xs ; Pmax = 3·V·E / Xs — Power–angle relation (W), Ra neglected; δ load angle.