Control Systems — formula sheet
Instrumentation Engineering · GATE IN · SI units. Drafted with Aria, checked by the AiCanCode.org team.
Open-loop and Closed-loop Systems, Effects of Feedback
T(s) = C(s)/R(s) = G(s) / (1 + G(s)H(s))— Closed-loop transfer function with negative feedback; G forward path, H feedback path; use1 − GHfor positive feedback.E(s) = R(s) / (1 + G(s)H(s))— Actuating error signal, with E = R − H·C.S_G = (∂T/T)/(∂G/G) = 1 / (1 + GH)— Sensitivity of T to forward-path changes (dimensionless); small-change result.S_H = −GH / (1 + GH)— Sensitivity of T to the feedback element; ≈ −1 at high loop gain.
Mathematical Modelling of Physical Systems
G(s) = C(s)/R(s)— Transfer function: Laplace transform of output over input with zero initial conditions; LTI systems only.X(s)/F(s) = 1 / (M·s² + B·s + K)— Mass-spring-damper; M in kg, B in N·s/m, K in N/m.ωn = √(K/M),ζ = B / (2·√(K·M))— Natural frequency (rad/s) and damping ratio of the mass-spring-damper.Vc(s)/Vi(s) = 1 / (LC·s² + RC·s + 1)— Series RLC, output across C;ωn = 1/√(LC),ζ = (R/2)·√(C/L).H(s)/Qi(s) = R / (A·R·s + 1)— Liquid-level tank; A area (m²), R = dh/dq (s/m²); for q = k√h, R = 2h0/q0.- Force–voltage analogy: M ↔ L, B ↔ R, K ↔ 1/C, velocity ↔ current. Force–current analogy: M ↔ C, B ↔ 1/R, K ↔ 1/L, velocity ↔ voltage.
Block Diagram Reduction and Signal Flow Graphs
Series: G1·G2;Parallel: G1 ± G2;Loop: G / (1 ± GH)— Basic reduction rules (plus sign in the denominator for negative feedback).T = (Σ Pk·Δk) / Δ— Mason's gain formula; Pk = gain of k-th forward path.Δ = 1 − ΣLi + ΣLiLj − ΣLiLjLk + …— Graph determinant: individual loop gains (with their signs), then products of non-touching pairs, triples, …Δk— Δ with all loops touching the k-th forward path removed.
Time Response of First and Second-Order Systems
c(t) = K·(1 − e^(−t/τ))— First-order unit-step response; reaches 63.2 % at t = τ;t_s(2 %) ≈ 4τ.T(s) = ωn² / (s² + 2ζωn·s + ωn²)— Standard second-order form.ωd = ωn·√(1 − ζ²)— Damped natural frequency (rad/s), 0 < ζ < 1.t_r = (π − θ)/ωd,θ = cos⁻¹ζ(rad) — Rise time, 0 to 100 %.t_p = π/ωd— Peak time (s).Mp = e^(−πζ/√(1 − ζ²))— Peak overshoot as a fraction; depends only on ζ.t_s ≈ 4/(ζωn)(2 % band),t_s ≈ 3/(ζωn)(5 % band) — Settling time (s), envelope approximation.
Steady-State Errors and Error Constants
e_ss = lim(s→0) s·R(s) / (1 + G(s)H(s))— Final value theorem, unity feedback; valid only for a stable closed loop.Kp = lim(s→0) G(s)H(s)— Position error constant (dimensionless);e_ss = 1/(1 + Kp)for a unit step.Kv = lim(s→0) s·G(s)H(s)— Velocity error constant (s⁻¹);e_ss = 1/Kvfor a unit ramp t.Ka = lim(s→0) s²·G(s)H(s)— Acceleration error constant (s⁻²);e_ss = 1/Kafor a unit parabola t²/2.- Type N = number of open-loop poles at s = 0. Type 0: step error finite; type 1: step error 0, ramp error finite; type 2: ramp error 0, parabola error finite.
Routh-Hurwitz Stability Criterion
a0·sⁿ + a1·sⁿ⁻¹ + … + an = 0— Characteristic equation, from 1 + G(s)H(s) = 0.b1 = (a1·a2 − a0·a3)/a1,b2 = (a1·a4 − a0·a5)/a1— Third-row elements of the Routh array.- Number of sign changes in the first column = number of right-half-plane roots.
a1·a2 > a0·a3(all ai > 0) — Necessary and sufficient stability condition for a cubic.- Row of zeros: form the auxiliary polynomial A(s) from the row above and replace the zero row with dA/ds; roots of A(s) = 0 give the symmetric roots (±jω at the critical gain).
Root Locus Technique
Σ∠(s − zi) − Σ∠(s − pj) = ±180°(2q + 1)— Angle condition for a point on the locus (K > 0).K = Π|s − pj| / Π|s − zi|— Magnitude condition: gain at a point on the locus.θa = (2q + 1)·180° / (n − m)— Asymptote angles; n poles, m zeros.σa = (Σ poles − Σ zeros) / (n − m)— Centroid of the asymptotes.dK/ds = 0, withK = −D(s)/N(s)— Breakaway and break-in points (keep roots on the real-axis locus with K > 0).φd = 180° − Σθ(other poles) + Σθ(zeros)— Angle of departure from a complex pole.
Bode Plots
|G|dB = 20·log10|G(jω)|— Magnitude in decibels.∠G(jω) = Σ∠(zero factors) − Σ∠(pole factors)— Phase (degrees); for1/(1 + jωT), the phase is−tan⁻¹(ωT).ωc = 1/T— Corner frequency of(1 + jωT); slope change ±20 dB/decade, true curve 3 dB off the asymptotes at ωc.- Pole at origin
1/(jω)ᴺ: slope −20N dB/decade through 0 dB at ω = 1 rad/s; phase −90N°. Mr = 1/(2ζ·√(1 − ζ²)),ωr = ωn·√(1 − 2ζ²)— Resonant peak and frequency of a second-order system (ζ < 0.707).ωb = ωn·√[(1 − 2ζ²) + √(4ζ⁴ − 4ζ² + 2)]— Closed-loop bandwidth (−3 dB) of the standard second-order system.
Polar and Nyquist Plots, Nyquist Stability Criterion
Z = N + P— Nyquist criterion; N = clockwise encirclements of −1 + j0 by G(jω)H(jω) (counter-clockwise counts negative), P = open-loop poles in the RHP, Z = closed-loop poles in the RHP. Stable ⇔ Z = 0.Im[G(jω)H(jω)] = 0— Gives the phase-crossover frequency and the real-axis intercept.∠e^(−jωT) = −ωTrad — Dead time rotates the plot without changing |G|.
Gain Margin and Phase Margin
∠G(jωpc)H(jωpc) = −180°— Defines the phase crossover frequency ωpc (rad/s).GM = 1/|G(jωpc)H(jωpc)|,GM(dB) = −20·log10|G(jωpc)H(jωpc)|— Gain margin.|G(jωgc)H(jωgc)| = 1— Defines the gain crossover frequency ωgc (rad/s).PM = 180° + ∠G(jωgc)H(jωgc)— Phase margin (degrees).ζ ≈ PM/100— Approximate damping from phase margin (PM in degrees, up to about 60°).Td,max = PM(rad)/ωgc— Largest dead time the loop tolerates (s).
P, PI and PID Controllers
u(t) = Kp·[e + (1/Ti)·∫e dt + Td·de/dt]— Ideal (ISA) PID; Ti integral time (s), Td derivative time (s).u(t) = Kp·e + Ki·∫e dt + Kd·de/dt— Parallel form;Ki = Kp/Ti(s⁻¹),Kd = Kp·Td(s).C(s) = Kp·(1 + 1/(Ti·s) + Td·s)— PID transfer function.PB (%) = 100/Kp— Proportional band (normalised signals).- Ziegler–Nichols (closed loop): P:
Kp = 0.5Ku; PI:Kp = 0.45Ku,Ti = Pu/1.2; PID:Kp = 0.6Ku,Ti = Pu/2,Td = Pu/8.
Lead, Lag and Lead-Lag Compensators
Gc(s) = (1 + aT·s)/(1 + T·s), a > 1 — Lead compensator: zero at −1/(aT) nearer the origin than the pole at −1/T.φm = sin⁻¹[(a − 1)/(a + 1)],a = (1 + sin φm)/(1 − sin φm)— Maximum phase lead.ωm = 1/(T·√a)— Frequency of maximum lead (geometric mean of the corners); gain there√a= 10·log10(a) dB.Gc(s) = (1 + T·s)/(1 + bT·s), b > 1 — Lag compensator: pole at −1/(bT) nearer the origin than the zero at −1/T; high-frequency gain 1/b.- Equivalent textbook form: lead
(1 + T·s)/(1 + αT·s)with α < 1 (α = 1/a); lag(1 + T·s)/(1 + βT·s)with β > 1.
State-Space Representation
ẋ = A·x + B·u— State equation; x state vector (n×1), A system matrix (n×n), B input matrix (n×m).y = C·x + D·u— Output equation; C output matrix (p×n), D feed-through matrix (p×m).G(s) = C·(sI − A)⁻¹·B + D— Transfer function from a state model.det(sI − A) = 0— Characteristic equation; eigenvalues of A are the poles (unless cancelled).Ã = P⁻¹AP,B̃ = P⁻¹B,C̃ = CP— Similarity transform; same eigenvalues and transfer function.
Solution of State Equations, Controllability and Observability
Φ(t) = e^(At) = L⁻¹[(sI − A)⁻¹]— State transition matrix; Φ(0) = I, Φ(−t) = Φ⁻¹(t).x(t) = Φ(t)·x(0) + ∫₀ᵗ Φ(t − τ)·B·u(τ) dτ— Complete solution: zero-input plus zero-state response.Qc = [B AB A²B … Aⁿ⁻¹B]— Controllability matrix; controllable ⇔ rank Qc = n.Qo = [C; CA; CA²; …; CAⁿ⁻¹]— Observability matrix (rows stacked); observable ⇔ rank Qo = n.
On-off and Time-delay Systems
θ = L/v— Dead time of a conveyor (s); L in m, v in m/s. For plug flow in a pipe,θ = V/Q.G(s) = K·e^(−θs)/(τs + 1)— First-order plus dead time (FOPDT) process model.e^(−θs) ≈ (1 − θs/2)/(1 + θs/2)— First-order Padé approximation of dead time.t = τ·ln[(y_final − y_start)/(y_final − y_end)]— Time for a first-order variable to travel between switching limits in on-off control.N(A) = 4M/(πA)— Describing function of an ideal relay with output ±M and input amplitude A.