Process Equipment Design

Process Equipment Design — formula sheet

Chemical Engineering · GATE CH · SI units. Drafted with Aria, checked by the AiCanCode.org team.

Materials of construction and corrosion allowance

  • t = t_calc + CA — Nominal thickness before rounding up to plate; t_calc thickness for loads (mm), CA corrosion allowance (mm).
  • CA = r_c × n — Corrosion allowance for uniform corrosion; r_c corrosion rate (mm/year), n design life (years).
  • r_c = 87.6 × W / (ρ × A × τ) — Corrosion rate from coupon test (mm/year); W mass loss (mg), ρ density (g/cm³), A area (cm²), τ exposure time (h).
  • 1 mpy = 0.0254 mm/year — Unit conversion (mils per year).

Design codes: IS 2825 and ASME Section VIII

  • t = P·Di / (2·f·J − P) — IS 2825 cylindrical shell; t (mm), P design gauge pressure (MPa), Di inside diameter (mm), f allowable stress at design temperature (MPa, from code), J joint efficiency (–).
  • t = P·R / (S·E − 0.6·P) — ASME VIII Div. 1 hoop thickness; R inside radius (mm), S allowable stress (MPa), E joint efficiency; valid for P ≤ 0.385·S·E.
  • t = P·R / (2·S·E + 0.4·P) — ASME VIII Div. 1 longitudinal thickness (usually about half the hoop value).
  • MAWP = S·E·t_c / (R + 0.6·t_c) — Maximum allowable working pressure (MPa); t_c corroded thickness (mm).
  • P_test ≈ 1.3 × MAWP × (S_test / S_design) — ASME VIII Div. 1 hydrotest pressure; confirm with current code edition.

Thin-walled pressure vessels under internal pressure

  • σ_h = P·r / t — Hoop stress in a thin cylinder (MPa); P (MPa), r radius (mm), t thickness (mm); t/D below about 1/20.
  • σ_l = P·r / (2·t) — Longitudinal stress in a closed thin cylinder (MPa).
  • σ = P·r / (2·t) — Membrane stress in a thin sphere, all directions (MPa).
  • t = P·Di / (4·f·J − P) — Design thickness of a spherical shell (mm).
  • ε_h = (σ_h − ν·σ_l) / E — Hoop strain; E Young's modulus (MPa), ν Poisson's ratio.
  • ΔV/V = (P·r / (2·t·E))·(5 − 4ν) — Volumetric strain of a closed thin cylinder.

Vessels under external pressure and stiffening rings

  • P_c = (2·E / (1 − ν²))·(t / Do)³ — Elastic collapse pressure of a long cylinder (MPa); about 2.2·E·(t/Do)³ for ν = 0.3; Do outside diameter (mm).
  • P_c = 2.6·E·(t / Do)^2.5 / (L / Do − 0.45·(t / Do)^0.5) — Collapse pressure of a short cylinder (ν = 0.3); L unsupported length (mm).
  • L_c = 1.11·Do·(Do / t)^0.5 — Critical length separating long and short behaviour (mm).
  • P_a = 4·B / (3·Do / t) — ASME VIII Div. 1 allowable external pressure for Do/t ≥ 10; B from code material chart (MPa).
  • I_req = P_c·Ls·Do³ / (24·E) — Second moment of area needed for a stiffening ring with its shell strip (mm⁴); Ls ring spacing (mm).

Design of heads and closures

  • t = P·Di / (4·S·E − 0.4·P) — Hemispherical head (mm).
  • t = P·Di / (2·S·E − 0.2·P) — 2:1 semi-ellipsoidal head (mm).
  • t = P·L·M / (2·S·E − 0.2·P), M = ¼·(3 + √(L / r)) — Torispherical head; L crown radius (mm), r knuckle radius (mm); M ≈ 1.77 for r = 0.06·L.
  • t = P·Di / (2·cos α·(S·E − 0.6·P)) — Conical head or section; α half-apex angle ≤ 30°.
  • t = d·√(C·P / (S·E)) — Flat unstayed head; d effective diameter (mm), C attachment factor from code (–).
  • V = π·Di³ / 24 — Volume of a 2:1 ellipsoidal head (m³ with Di in m); inside depth Di/4.

Flanges, gaskets and bolting

  • b = b0 (b0 ≤ 6.3 mm); b = 2.5·√b0 (b0 > 6.3 mm) — Effective gasket width (mm); b0 = N/2 for a flat ring of contact width N.
  • W_m2 = π·b·G·y — Bolt-up (seating) load (N); G gasket load-reaction diameter (mm), y seating stress (MPa, from code table).
  • W_m1 = (π/4)·G²·P + 2·π·b·G·m·P — Operating bolt load (N); m gasket factor (–), P (MPa).
  • A_m = max(W_m1 / S_b, W_m2 / S_a) — Minimum total bolt root area (mm²); S_a, S_b bolt allowable stress at ambient and design temperature (MPa).
  • N_min = A_b·S_a / (2·π·y·G) — Minimum gasket width to avoid crushing (mm); A_b actual bolt root area (mm²).

Nozzles, openings and reinforcement

  • A = d·t_r — Reinforcement area required (mm²); d finished opening diameter, corroded (mm), t_r shell thickness required for pressure (mm).
  • A1 = d·(t − t_r) — Excess area in the shell (mm²); t available corroded shell thickness (mm).
  • A2 = 2·h·(t_n − t_rn), h = min(2.5·t, 2.5·t_n + t_e) — Excess area in the nozzle neck (mm²); t_n, t_rn available and required neck thickness (mm), t_e pad thickness (mm).
  • A5 = (D_p − d − 2·t_n)·t_e — Reinforcing pad area (mm²); D_p pad outside diameter ≤ 2d (mm).
  • A1 + A2 + A4 + A5 ≥ A — Adequacy condition (A4 weld area).

Vessel supports

  • σ_w = W / (π·D_s·t_s) — Axial stress in a skirt from weight (MPa); W (N), D_s skirt diameter (mm), t_s thickness (mm).
  • σ_b = 4·M / (π·D_s²·t_s) — Axial stress in a skirt from overturning moment (MPa); M (N·mm).
  • f_c = W / (π·D_b·L_b) + 4·M / (π·D_b²·L_b) — Bearing pressure under a base ring (MPa); D_b ring mean diameter, L_b ring width (mm).
  • t_b = L_r·√(3·f_c / f_r) — Base ring thickness (mm); L_r outward projection (mm), f_r allowable bending stress (MPa).
  • F_bolt = 4·M / (N·D_bc) − W_min / N — Tension per anchor bolt (N); N bolts, D_bc bolt circle diameter (mm), W_min minimum weight (N).

Atmospheric storage tank design

  • p = ρ·g·h — Hydrostatic pressure at depth h (Pa).
  • t = ρ·g·h·D / (2·S·J) — Shell thickness from liquid head (m, with D in m and S in Pa).
  • t_d = 4.9·D·(H − 0.3)·G / S_d + CA — API 650 one-foot method, design condition; t (mm), D (m), H liquid level above bottom of course (m), G specific gravity, S_d (MPa).
  • t_t = 4.9·D·(H − 0.3) / S_t — API 650 one-foot method, hydrotest condition (no CA); S_t (MPa).

Tall vessels: wind and seismic loads

  • p_z = 0.6·V_z² — Design wind pressure (N/m²); V_z design wind speed (m/s) = V_b·k1·k2·k3 per IS 875 Part 3.
  • F = C_f·A_e·p_z — Wind force on a section (N); C_f force coefficient, A_e effective projected area (m²).
  • M = w·H² / 2 — Base moment for uniform wind load w (N/m) over height H (m).
  • V_B = A_h·W, A_h = (Z/2)·(I/R)·(S_a/g) — Seismic base shear (N) per IS 1893; factors from code.
  • σ_z = P·D / (4·t) ± 4·M / (π·D²·t) − W / (π·D·t) — Combined longitudinal stress (MPa); + windward, − leeward.
  • V_c = f_n·D / S — Critical wind speed for vortex shedding (m/s); f_n natural frequency (Hz), S ≈ 0.2.

Process and mechanical design of shell-and-tube heat exchangers

  • Q = U·A·F·ΔT_lm — Heat duty (W); F LMTD correction factor for multipass (–).
  • ΔT_lm = (ΔT1 − ΔT2) / ln(ΔT1 / ΔT2) — Log-mean temperature difference (K).
  • A = N_t·π·d_o·L — Outside area of N_t tubes (m²).
  • 1/U_o = 1/h_o + R_do + d_o·ln(d_o/d_i)/(2·k_w) + (d_o/d_i)·R_di + (d_o/d_i)/h_i — Overall coefficient on outside area (W/m²·K).
  • D_b = d_o·(N_t / K1)^(1/n1) — Tube bundle diameter; K1, n1 from data book.

Process design of tray columns

  • F_LV = (L_w / V_w)·√(ρ_V / ρ_L) — Flow parameter (mass flows).
  • u_f = K1·√((ρ_L − ρ_V) / ρ_V) — Flooding velocity on net area (m/s); K1 from Fair's chart.
  • h_ow = 750·(L_w / (ρ_L·l_w))^(2/3) — Crest over weir (mm liquid); L_w (kg/s), l_w weir length (m).
  • h_d = 51·(u_h / C0)²·(ρ_V / ρ_L) — Dry-plate pressure drop (mm liquid).
  • ΔP_t = 9.81 × 10⁻³·h_t·ρ_L — Tray pressure drop (Pa) from total head h_t (mm).
  • h_b = (h_w + h_ow) + h_t + h_dc ≤ ½·(l_t + h_w) — Downcomer back-up limit (mm).

Process design of packed columns

  • F_LV = (L* / V*)·√(ρ_V / ρ_L) — Flow parameter for the generalised pressure-drop correlation.
  • K4 = 13.1·(V*)²·F_p·(μ_L / ρ_L)^0.1 / (ρ_V·(ρ_L − ρ_V)) — GPDC capacity parameter; V* gas mass flux (kg/m²·s), F_p packing factor (m⁻¹), μ_L (Pa·s).
  • % flooding = 100·√(K4_design / K4_flood) — Approach to flooding.
  • Z = N_OG·H_OG — Packed height (m) from transfer units, or Z = N·HETP.

Design of agitated vessels and jackets

  • Re = ρ·N·D_a² / μ — Impeller Reynolds number; N speed (rev/s), D_a impeller diameter (m).
  • P = N_P·ρ·N³·D_a⁵ — Agitator power, turbulent baffled tank (W); N_P power number from chart.
  • P = K_L·μ·N²·D_a³ — Agitator power, laminar regime (W).
  • N2 = N1·(D1 / D2)^(2/3) — Scale-up at constant power per unit volume.
  • t = (M·cp / (U·A))·ln((T_s − T_1) / (T_s − T_2)) — Batch heating time with an isothermal medium (s).

Piping design and line sizing

  • D = √(4·Q / (π·v)) — Inside diameter for a chosen velocity (m); Q (m³/s), v (m/s).
  • Re = ρ·v·D / μ — Reynolds number.
  • ΔP = f·(L / D)·(ρ·v² / 2) + ΣK·(ρ·v² / 2) — Pipe and fitting losses (Pa); f Darcy friction factor (64/Re laminar).
  • t = P·D_o / (2·(S·E + P·Y)) — Straight-pipe pressure thickness (ASME B31.3); Y = 0.4 for steels below about 480 °C; add CA and divide by 0.875 for mill tolerance.
  • ΔL = α·L·ΔT — Thermal expansion (m); α ≈ 12 × 10⁻⁶ K⁻¹ for carbon steel.