Process Calculations — formula sheet
Chemical Engineering · GATE CH · SI units. Drafted with Aria, checked by the AiCanCode.org team.
Units, Dimensions and Unit Conversions
1 N = 1 kg·m/s²;1 Pa = 1 N/m²;1 J = 1 N·m;1 W = 1 J/s— SI derived units.1 atm = 101.325 kPa = 1.01325 bar = 760 mmHg = 14.696 psi;1 bar = 10⁵ Pa— pressure conversions.T(K) = t(°C) + 273.15;T(°R) = t(°F) + 459.67;ΔT(K) = ΔT(°F) / 1.8— temperature scales; differences carry no offset.P_abs = P_gauge + P_atm— gas laws need absolute pressure.R = 8.314 J/(mol·K) = 8.314 kPa·m³/(kmol·K) = 0.08206 L·atm/(mol·K)— universal gas constant.
Mole Concept, Composition and Concentration Expressions
n = m / M— n amount (kmol); m mass (kg); M molar mass (kg/kmol).x_i = n_i / Σn;w_i = m_i / Σm— mole and mass fractions (dimensionless, each set sums to 1).M_avg = Σ x_i·M_i = 1 / Σ(w_i / M_i)— average molar mass of a mixture (kg/kmol).C = n_solute / V_solution(mol/L) ;m = n_solute / m_solvent(mol/kg) — molarity and molality.
Ideal Gas Law, Partial Pressure and Gas Mixture Calculations
P·V = n·R·T— P absolute pressure (Pa); V volume (m³); n amount (mol); T absolute temperature (K).ρ = P·M / (R·T)— gas density (kg/m³) with P in kPa, M in kg/kmol, R = 8.314 kPa·m³/(kmol·K).p_i = y_i·P;Σ p_i = P— Dalton's law; p_i partial pressure, y_i mole fraction.V_m = 22.414 m³/kmol— molar volume at 0 °C and 1 atm.P·V = Z·n·R·T— real gas; Z compressibility factor from T_r = T/T_c and P_r = P/P_c.
Vapour Pressure, Antoine Equation and Raoult's Law
log₁₀ P_sat = A − B / (T + C)— Antoine; P_sat and T in the units of the constants' source (often mmHg and °C).ln(P₂/P₁) = −(ΔH_vap / R)·(1/T₂ − 1/T₁)— Clausius–Clapeyron; T in K, ΔH_vap in J/mol.y_i·P = x_i·P_i,sat— Raoult's law for ideal liquid and vapour.P_bubble = Σ x_i·P_i,sat;1 / P_dew = Σ y_i / P_i,sat— bubble and dew pressures.α_AB = P_A,sat / P_B,sat— relative volatility of an ideal binary.
Humidity, Saturation and Use of the Psychrometric Chart
H = 0.622·p_w / (P − p_w)— humidity (kg water/kg dry air); p_w water vapour partial pressure; P total pressure.RH = p_w / p_sat(T)— relative humidity, p_sat at the dry-bulb temperature.% saturation = H / H_sat × 100— percentage (absolute) saturation.p_sat(T_dp) = p_w— dew point from steam tables.c_s = 1.005 + 1.88·H— humid heat, kJ/(kg dry air·K).v_H = (1/28.97 + H/18.02)·R·T / P— humid volume, m³/kg dry air (R = 8.314 kPa·m³/(kmol·K), T in K, P in kPa).
Stoichiometry, Limiting and Excess Reactants, Conversion and Yield
limiting reactant = smallest n_i,0 / |ν_i|— feed moles divided by stoichiometric coefficient.% excess = (n_fed − n_theoretical) / n_theoretical × 100— n_theoretical needed to consume all limiting reactant.X_A = (n_A,0 − n_A) / n_A,0— fractional conversion of reactant A.Y_feed = X_A × Y_reacted— yield on feed = conversion × yield on reactant consumed.S = n_desired / n_undesired— selectivity.
Degree-of-Freedom Analysis for Process Units
DOF = N_unknowns − N_independent equations— DOF = 0 solvable; > 0 under-specified; < 0 over-specified.Non-reactive unit: independent material balances = number of species— the total balance is not extra.Splitter: one independent material balance; DOF = outlets − 1— known feed, outlets share the feed composition.
Material Balances Without Reaction
Input − Output = Accumulation— no generation or consumption; at steady state Input = Output.D / F = (x_F − x_B) / (x_D − x_B)— two-product separator.F·(1 − w_F) = P·(1 − w_P)— tie component (dry solid) in a dryer; w moisture mass fraction (wet basis).
Material Balances on Multiple-Unit Processes
Overall: Σ fresh feeds = Σ final products— internal streams cancel (steady state, no reaction).Recovery of i in stream j = n_j·x_i,j / (n_F·x_i,F)— fraction of feed component i reporting to stream j.
Material Balances with Chemical Reaction and Extent of Reaction
n_i = n_i,0 + ν_i·ξ— single reaction; ν_i negative for reactants; ξ extent (mol or mol/s).n_i = n_i,0 + Σ_j ν_ij·ξ_j— multiple independent reactions.ξ = X_A·n_A,0 / |ν_A|— extent from conversion.Σ atoms of each element in = Σ atoms out— element balances (count only independent ones).
Recycle, Bypass and Purge Stream Calculations
X_single-pass = (A into reactor − A out of reactor) / A into reactorX_overall = (A in fresh feed − A leaving process) / A in fresh feedReactor feed = F + R;Recycle ratio = R / F— state the definition used.P·y_I = F·x_I,F— purge removes the inert I that enters with the fresh feed.
Combustion Calculations, Excess Air and Flue Gas Analysis
CₓHᵧ + (x + y/4)·O₂ → x·CO₂ + (y/2)·H₂O— complete combustion.Theoretical air = theoretical O₂ / 0.21;N₂ = 3.76 × O₂ fed— air 21 mol % O₂.% excess air = (O₂ fed − O₂ theoretical) / O₂ theoretical × 100— theoretical O₂ for complete combustion.% excess air = (O₂ − 0.5·CO) / (0.266·N₂ − (O₂ − 0.5·CO)) × 100— from a dry (Orsat) analysis in mol %, nitrogen-free fuel.
Heat Capacity, Sensible Heat and Latent Heat Calculations
Q = m·c_p·ΔT— Q (J); m (kg); c_p (J/(kg·K)); ΔT (K).ΔH = n·∫C_p dT; forC_p/R = A + B·T + D·T⁻²:ΔH/R = A·(T₂ − T₁) + (B/2)·(T₂² − T₁²) − D·(1/T₂ − 1/T₁)— T in K.C_p − C_v = R— ideal gas.Q = m·λ— latent heat; λ (J/kg).ΔH_vap,2 = ΔH_vap,1·[(T_c − T₂) / (T_c − T₁)]^0.38— Watson correlation, T in K.
Standard Heat of Formation, Reaction and Combustion
ΔH_r° = Σ ν·ΔH_f°(products) − Σ ν·ΔH_f°(reactants)— kJ per mol of reaction as written, 25 °C.ΔH_r° = Σ ν·ΔH_c°(reactants) − Σ ν·ΔH_c°(products)— from heats of combustion.ΔH_r(T) = ΔH_r° + ΔC_p·(T − 298.15);ΔC_p = Σ ν_i·C_p,i— Kirchhoff, mean C_p.HHV − LHV = n_H₂O × 44.0 kJ/mol— latent heat of water at 25 °C.
Energy Balances on Non-Reactive Processes
ΔU + ΔE_k + ΔE_p = Q − W— closed system; Q into system positive, W by system positive.ΔḢ + ΔĖ_k + ΔĖ_p = Q̇ − Ẇ_s— open system at steady state (kW).Ė_k = ṁ·u²/2;Ė_p = ṁ·g·z— u velocity (m/s), z height (m).ΔH = 0— throttling valve.
Energy Balances on Reactive Processes and Adiabatic Flame Temperature
Q = ξ·ΔH_r° + Σ n_out·Ĥ_out − Σ n_in·Ĥ_in— heat-of-reaction method; Ĥ sensible enthalpy relative to 25 °C.Ĥ_i = ΔH_f,i° + ∫C_p,i dT— heat-of-formation method (elements at 25 °C as reference).T_ad = 298.15 + (−ξ·ΔH_r°) / Σ(n_out·C_p,mean)— adiabatic temperature, feed at 25 °C; ΔH_r° negative for exothermic reactions; include inerts and excess reactants in Σ n_out·C_p.
Heat of Solution and Mixing, Enthalpy-Concentration Charts
Q = n_solute·ΔĤ_s(r)— isothermal dissolution at 25 °C; ΔĤ_s(r) integral heat of solution per mol solute in r mol solvent.ΔĤ_dil = ΔĤ_s(r₂) − ΔĤ_s(r₁)— heat of dilution per mol solute.x_mix = (m₁·x₁ + m₂·x₂) / (m₁ + m₂)— adiabatic mixing on an H–x chart (mass basis, lever rule).Q = m_out·H_out − Σ m_in·H_in— energy balance with chart enthalpies (kJ/kg).
Unsteady-State Material and Energy Balances
dM/dt = ṁ_in − ṁ_out— total mass balance.C = C_in + (C₀ − C_in)·exp(−t/τ);τ = V/Q— well-mixed tank of constant volume.t = (m·c_p / (U·A))·ln[(T_s − T₀) / (T_s − T)]— batch heated by a coil at constant T_s.t = 2A·(√h₀ − √h) / k— gravity draining with outflow k·√h.