Fick's Law and Molecular Diffusion in Gases and Liquids
J_A = −D_AB · dC_A/dz— Fick's first law: diffusive molar flux J_A (mol/m²·s) relative to the molar-average velocity; D_AB diffusivity (m²/s); C_A concentration (mol/m³); z distance (m). Binary system, any instant.N_A = J_A + x_A (N_A + N_B)— Total flux N_A (mol/m²·s) relative to fixed axes = diffusion + bulk flow; x_A mole fraction.∂C_A/∂t = D_AB · ∂²C_A/∂z²— Fick's second law: unsteady diffusion, constant D, no reaction, stagnant medium.N_A = D_AB (p_A1 − p_A2) / (R·T·z)— Steady equimolar counter-diffusion (N_A = −N_B) through a gas film of thickness z (m); p in Pa; R = 8.314 J/(mol·K); T in K.N_A = D_AB·P (p_A1 − p_A2) / (R·T·z·p_BM)— Steady diffusion of A through stagnant B; P total pressure (Pa); p_BM = (p_B2 − p_B1)/ln(p_B2/p_B1) log-mean partial pressure of B (Pa).D₂ = D₁ (T₂/T₁)^1.75 (P₁/P₂)— Gas diffusivity correction (Fuller form; exponent 1.5 from kinetic theory). For liquids D·μ/T ≈ constant (Stokes–Einstein, Wilke–Chang).
Diffusion in Solids
N_A = D_AB (C_A1 − C_A2) / z— Steady diffusion through a flat slab of thickness z (m); C in the solid (mol/m³).w_A = 2π·L·D_AB (C_A1 − C_A2) / ln(r₂/r₁)— Total rate (mol/s) through a hollow cylinder of length L, radii r₁ < r₂ (m).w_A = 4π·D_AB (C_A1 − C_A2) / (1/r₁ − 1/r₂)— Total rate (mol/s) through a spherical shell.C_A = S·p_A / 22.414— Gas concentration in a solid (kmol/m³) from solubility S (m³ STP/(m³·atm)) and partial pressure p_A (atm).D_eff = ε·D_AB / τ— Effective diffusivity in a porous solid; ε porosity, τ tortuosity (dimensionless).D_K = 97·r·√(T/M)— Knudsen diffusivity (m²/s); r pore radius (m); T (K); M (kg/kmol). Independent of pressure.(C − C₀)/(C_s − C₀) = 1 − erf[x / (2√(D·t))]— Semi-infinite solid with constant surface concentration C_s, initial C₀; x depth (m); t time (s).D = D₀·exp(−Q/(R·T))— Arrhenius temperature dependence; Q activation energy (J/mol).
Mass Transfer Coefficients and Correlations
N_A = k_G Δp_A = k_y Δy_A = k_c ΔC_A— Gas-phase coefficients: k_G (mol/m²·s·Pa), k_y (mol/m²·s), k_c (m/s).k_y = k_G·P,k_c = k_G·R·T,k_x = k_L·C— Conversions (ideal gas; C total molar concentration of liquid, mol/m³).Sh = k_c·L/D_AB,Sc = μ/(ρ·D_AB),Re = ρ·u·L/μ— Sherwood, Schmidt and Reynolds numbers; L characteristic length (m).Sh = 0.023·Re^0.83·Sc^(1/3)— Turbulent flow in a pipe or wetted-wall column (Linton–Sherwood), Re > about 4000.Sh = 2 + 0.6·Re^0.5·Sc^(1/3)— Single sphere (Frössling / Ranz–Marshall); Sh = 2 in stagnant fluid.Sh_L = 0.664·Re_L^0.5·Sc^(1/3)— Laminar flat plate, average over length L.j_D = (k_c/u)·Sc^(2/3) = j_H = f/2— Chilton–Colburn analogy (0.6 < Sc < 2500); givesk_c = (h/(ρ·c_p))·(Pr/Sc)^(2/3).
Mass Transfer Theories: Film, Penetration and Surface Renewal
k = D_AB / δ— Film theory; δ fictitious film thickness (m); k ∝ D.k_av = 2·√(D_AB / (π·t_c))— Higbie penetration theory, average over exposure time t_c (s); k ∝ D^0.5.k = √(D_AB·s)— Danckwerts surface renewal; s fractional renewal rate (s⁻¹); k ∝ D^0.5.k_A/k_B = (D_A/D_B)^n— n = 1 (film), 0.5 (penetration, renewal), 2/3 (boundary layer).
Interphase Mass Transfer and Overall Coefficients
N_A = k_y (y_b − y_i) = k_x (x_i − x_b)— Two-resistance theory; interface (x_i, y_i) at equilibrium; interface found with a line of slope −k_x/k_y from the bulk point.1/K_y = 1/k_y + m/k_x— Overall gas-phase coefficient (mol/m²·s); m slope of equilibrium line y = m·x; N_A = K_y (y_b − y*).1/K_x = 1/k_x + 1/(m·k_y)— Overall liquid-phase coefficient; N_A = K_x (x* − x_b).1/K_G = 1/k_G + H/k_L,1/K_L = 1/k_L + 1/(H·k_G)— With Henry's law p_A = H·C_A (H in Pa·m³/mol); K_G (mol/m²·s·Pa), K_L (m/s).
Gas Absorption: Minimum Solvent Rate and Number of Stages
Y = y/(1 − y),X = x/(1 − x)— Mole ratios on solute-free basis; G_s = G(1 − y), L_s = L(1 − x) constant.G_s (Y₁ − Y₂) = L_s (X₁ − X₂)— Operating line (subscript 1 rich/bottom end, 2 lean/top end).(L_s/G_s)_min = (Y₁ − Y₂) / (X₁* − X₂)— Minimum solvent with the pinch at the rich end; X₁* in equilibrium with Y₁ (use the tangent point if the curve is concave up). Operate at 1.2–2 × minimum.A = L/(m·G)— Absorption factor (stripping factor S = 1/A).N = ln[((y₁ − m·x₂)/(y₂ − m·x₂))(1 − 1/A) + 1/A] / ln A— Kremser equation, ideal stages, dilute, linear equilibrium.
Packed Tower Design: HTU and NTU
Z = H_OG × N_OG— Packed height (m); use only matching HTU–NTU pairs.H_OG = G/(K_y·a)— Overall gas-phase HTU (m); G molar flux (kmol/m²·s); K_y·a (kmol/m³·s).N_OG = ∫ dy/(y − y*) = (y₁ − y₂)/Δy_LM— Number of transfer units (log-mean form for straight lines).N_OG = ln[((y₁ − m·x₂)/(y₂ − m·x₂))(1 − 1/A) + 1/A] / (1 − 1/A)— Colburn equation; for A = 1, N_OG = (y₁ − y₂)/(y₂ − m·x₂).H_OG = H_G + (m·G/L)·H_L— Combining film HTUs.HETP = H_OG · ln S / (S − 1), S = m·G/L — HETP from H_OG (equal when S = 1).
Distillation: VLE, Relative Volatility and Flash Distillation
y_i·P = x_i·P_i^sat— Raoult + Dalton (ideal); K_i = y_i/x_i = P_i^sat/P.α_AB = (y_A/x_A)/(y_B/x_B)— Relative volatility (light/heavy); ideal: α = P_A^sat/P_B^sat.y = α·x / (1 + (α − 1)·x)— Equilibrium curve with constant α.y = −((1 − f)/f)·x + z/f— Flash operating line; f = V/F vaporised fraction; passes through (z, z).Σ z_i (K_i − 1)/(1 + f(K_i − 1)) = 0— Rachford–Rice multicomponent flash.
Batch and Differential Distillation, Rayleigh Equation
ln(F/W) = ∫ from x_W to x_F of dx/(y − x)— Rayleigh equation; F initial charge, W residue (mol); y in equilibrium with still liquid x.ln(F/W) = [ln(x_F/x_W) + α·ln((1 − x_W)/(1 − x_F))]/(α − 1)— Constant relative volatility.ln(F/W) = ln(x_F/x_W)/(K − 1)— Linear equilibrium y = K·x.x_D,avg = (F·x_F − W·x_W)/(F − W)— Average composition of the collected distillate.
McCabe-Thiele Method for Continuous Distillation
F = D + W,F·z_F = D·x_D + W·x_W— Overall and light-component balances.y = (R/(R + 1))·x + x_D/(R + 1)— Rectifying operating line; R = L/D reflux ratio.y = (L′/V′)·x − W·x_W/V′,L′ = L + q·F,V′ = V − (1 − q)·F— Stripping operating line and flows below the feed.y = (q/(q − 1))·x − z_F/(q − 1)— q-line; q = (H_V − H_F)/(H_V − H_L): 1 saturated liquid (vertical), 0 saturated vapour (horizontal).R_min = (x_D − y′)/(y′ − x′)— Minimum reflux from the pinch (x′, y′), usually q-line ∩ equilibrium curve.N_min = ln[(x_D/(1 − x_D))((1 − x_W)/x_W)] / ln α— Fenske equation at total reflux (includes reboiler).
Ponchon-Savarit Method and Minimum Reflux
Q′_D = H_D + Q_C/D,Q′_W = H_W − Q_B/W— Enthalpy coordinates of difference points Δ_D and Δ_W (kJ/kmol); Δ_D, F, Δ_W collinear.R = (Q′_D − H_V1)/(H_V1 − H_L0)— Reflux ratio from the lever rule on the H–x–y diagram.Q_C = (R + 1)·D·(H_V1 − H_L0)— Total-condenser duty with saturated reflux (kJ/h).F·H_F + Q_B = D·H_D + W·H_W + Q_C— Overall energy balance.Σ α_i z_i/(α_i − θ) = 1 − q,R_min + 1 = Σ α_i x_D,i/(α_i − θ)— Underwood equations (constant α); θ between the key volatilities.
Liquid-Liquid Extraction: Triangular Diagrams and Stage Calculations
F + S = M = E + R— Mixing point; x_A,M = (F·x_A,F + S·y_A,S)/(F + S); E, M, R on one tie line (lever rule).K = y_A/x_A,β = (y_A/y_B)/(x_A/x_B)— Distribution coefficient and selectivity (extract y, raffinate x).ε = K′·S/B— Extraction factor for immiscible carrier B and solvent S; equilibrium Y = K′·X on solute-free ratios.X₁ = X_F/(1 + ε)— Single stage with pure solvent.X_N/X_F = (ε − 1)/(ε^(N+1) − 1)— N counter-current stages with pure solvent (ε ≠ 1).
Leaching and Solid-Liquid Extraction
y_n = x_n— Ideal leaching stage: retained (underflow) solution has the same composition as the overflow.U·x_n−1 + V·x_n+1 = (U + V)·x_n— Solute balance on a washing stage with constant underflow solution U and overflow V (kg/h).Recovery = 1 − (solute in final underflow)/(solute fed)— Underflow = inerts + retained solution.
Humidification Operations and Cooling Towers
Y = 0.622·p_A/(P − p_A)— Absolute humidity (kg water/kg dry air) for air–water; p_A partial pressure of water.c_s = 1.005 + 1.88·Y— Humid heat (kJ/kg dry air·K).H = (1.005 + 1.88·Y)·t + 2501·Y— Enthalpy of moist air (kJ/kg dry air), t in °C, reference 0 °C liquid water.L·c_L (T_L2 − T_L1) = G_s (H₂ − H₁)— Cooling-tower energy balance; L water (kg/s), G_s dry air (kg/s).Z = (G_s/(K_Y·a))·∫ dH/(H* − H)— Merkel design equation; H* saturated-air enthalpy at water temperature.Range = T_in − T_out,Approach = T_out − T_wb,Effectiveness = Range/(Range + Approach)— Cooling-tower performance terms.
Drying: Drying Rate Curves and Drying Time
N = −(L_s/A)·dX/dt— Drying rate (kg/m²·h); L_s dry solid (kg); A drying area (m²); X dry-basis moisture (kg/kg).N_c = h (T − T_w)/λ_w = k_Y (Y_w − Y)— Constant drying rate; surface at the wet-bulb temperature T_w.t_c = (L_s/(A·N_c))·(X₁ − X_c)— Constant-rate drying time; X_c critical moisture.t_f = (L_s/(A·N_c))·(X_c − X*)·ln[(X_c − X*)/(X₂ − X*)]— Falling-rate time with rate linear in X; X* equilibrium moisture.t = (4a²/(π²·D_L))·ln[(8/π²)(X₁ − X*)/(X₂ − X*)]— Diffusion-controlled slab, half-thickness a (m), drying from both faces.
Adsorption Isotherms and Fixed-Bed Adsorption
q = q_max·K·C/(1 + K·C)— Langmuir isotherm; q (mol/kg or mg/g), q_max monolayer capacity, K (m³/mol or L/mg).q = K_F·C^(1/n)— Freundlich isotherm; 1/n < 1 favourable.V (C₀ − C_e) = m·q_e— Batch adsorption balance; V liquid volume, m adsorbent mass.t* = q_F·ρ_b·L / (u·C_F)— Stoichiometric time of a fixed bed; ρ_b bulk density (kg/m³); L bed length (m); u superficial velocity; C_F feed concentration (kg/m³).LUB = L·(1 − t_b/t*)— Length of unused bed at the breakpoint t_b; constant on scale-up at the same velocity.
Crystallisation and Membrane Separation Basics
S_F = f·C + S_ML,W_F − E = (1 − f)·C + W_ML— Crystal yield balances; C crystal mass, f = M_anhydrous/M_hydrate, E water evaporated, mother liquor saturated.J_w = A·(ΔP − Δπ)— Reverse-osmosis water flux (m³/m²·s); A water permeability (m/(s·Pa)); ΔP applied pressure difference; Δπ osmotic pressure difference (Pa).π = i·C·R·T— Van't Hoff osmotic pressure (Pa); i ions per formula unit; C (mol/m³).R = 1 − C_p/C_f— Observed solute rejection; C_p permeate, C_f feed concentration.J = ΔP/(μ·(R_m + R_f))— Flux through porous MF/UF membranes; R_m, R_f membrane and fouling resistances (m⁻¹).α_AB = P_A/P_B— Ideal selectivity of a gas-separation membrane (ratio of permeabilities).