Heat Transfer

Heat Transfer — formula sheet

Chemical Engineering · GATE CH · SI units. Drafted with Aria, checked by the AiCanCode.org team.

Fourier's Law and Steady One-Dimensional Conduction

  • q = −k·A·dT/dx — Fourier's law; q heat rate (W), k thermal conductivity (W/m·K), A area normal to heat flow (m²), dT/dx temperature gradient (K/m); valid at every point, steady or transient.
  • q = k·A·(T₁ − T₂)/L — plane wall, steady, no generation, constant k; L thickness (m).
  • k_m = k₀·[1 + β·(T₁ + T₂)/2] — mean conductivity for k = k₀(1 + βT); use in the plane-wall formula for the heat rate.
  • ρ·c·∂T/∂t = ∇·(k∇T) + q̇_g — heat conduction equation; ρ (kg/m³), c (J/kg·K), q̇_g generation (W/m³).
  • α = k/(ρ·c) — thermal diffusivity (m²/s).

Conduction Through Composite Walls, Cylinders, and Spheres

  • q = ΔT_overall/ΣR — series resistances, steady, no generation; R (K/W).
  • R = L/(k·A) — plane layer; L (m), k (W/m·K), A (m²).
  • R = 1/(h·A) — convective film; h (W/m²·K).
  • R = ln(r₂/r₁)/(2π·k·L) — cylindrical shell; r₁, r₂ inner and outer radii (m), L length (m).
  • R = (r₂ − r₁)/(4π·k·r₁·r₂) — spherical shell.
  • A_lm = (A₂ − A₁)/ln(A₂/A₁) — log-mean area of a cylinder; A_gm = √(A₁·A₂) for a sphere.

Critical Radius of Insulation

  • r_c = k/h — cylinder; k insulation conductivity (W/m·K), h outside coefficient (W/m²·K); heat loss is a maximum when the insulation outer radius equals r_c.
  • r_c = 2k/h — sphere.

Heat Generation in Solids

  • T_max − T_s = q̇·L²/(2k) — plane wall of half-thickness L (m), uniform generation q̇ (W/m³).
  • T_max − T_s = q̇·R²/(4k) — solid cylinder of radius R (m).
  • T_max − T_s = q̇·R²/(6k) — solid sphere.
  • T_s = T∞ + q̇·(V/A_s)/h — surface temperature from the overall balance; V/A_s = L (slab face), R/2 (cylinder), R/3 (sphere).

Extended Surfaces: Fin Efficiency and Effectiveness

  • m = √(h·P/(k·A_c)) — fin parameter (1/m); P perimeter (m), A_c cross-section (m²); pin fin m = √(4h/(k·d)).
  • q_f = √(h·P·k·A_c)·θ_b·tanh(m·L) — adiabatic tip; θ_b = T_b − T∞ (K); infinite fin: tanh → 1.
  • L_c = L + A_c/P — corrected length for a convective tip (m).
  • η_f = tanh(m·L)/(m·L) — fin efficiency (adiabatic tip).
  • ε_f = q_f/(h·A_c·θ_b) — fin effectiveness; infinite fin ε_f = √(k·P/(h·A_c)).

Unsteady Conduction and Lumped Capacitance Analysis

  • Bi = h·L_c/k_solid — Biot number; L_c = V/A_s (m); lumped analysis valid for Bi < 0.1.
  • (T − T∞)/(T_i − T∞) = exp(−t/τ) — lumped response; t time (s).
  • τ = ρ·c·V/(h·A_s) — time constant (s).
  • Fo = α·t/L_c² — Fourier number; lumped form θ/θ_i = exp(−Bi·Fo).
  • (T − T_s)/(T_i − T_s) = erf[x/(2√(α·t))] — semi-infinite solid, sudden surface temperature change.

Forced Convection: Dimensionless Numbers and Correlations

  • q = h·A·(T_s − T_f) — Newton's law of cooling; h (W/m²·K).
  • Re = ρ·u·L/μ, Pr = c_p·μ/k, Nu = h·L/k_fluid — dimensionless groups; u (m/s), μ (Pa·s), c_p (J/kg·K).
  • St = h/(ρ·c_p·u) = Nu/(Re·Pr) — Stanton number.
  • Nu = 0.023·Re^0.8·Pr^n — Dittus–Boelter, turbulent tube flow, Re > 10⁴, 0.7 < Pr < 160; n = 0.4 heating, 0.3 cooling.
  • Nu = 0.027·Re^0.8·Pr^(1/3)·(μ_b/μ_w)^0.14 — Sieder–Tate, turbulent, large viscosity variation.
  • Nu = 3.66 (uniform wall temperature), Nu = 4.36 (uniform flux) — laminar fully developed tube flow.
  • Nu_L = 0.664·Re_L^0.5·Pr^(1/3) — laminar flat plate, average; Re_L < 5 × 10⁵.

Thermal Boundary Layer and Heat Transfer Coefficient

  • h = −k_f·(∂T/∂y)_wall/(T_s − T∞) — h from the wall temperature gradient; k_f fluid conductivity.
  • δ = 5·x/√Re_x — laminar velocity boundary layer on a flat plate; x from leading edge (m).
  • δ/δ_t ≈ Pr^(1/3) — laminar flat plate.
  • Nu_x = 0.332·Re_x^0.5·Pr^(1/3) — local laminar flat plate; average h over 0–L is twice local h at L.
  • St·Pr^(2/3) = f/2 — Chilton–Colburn analogy (Fanning f).

Natural Convection Correlations

  • Gr = g·β·ΔT·L³/ν² — Grashof number; β = 1/T_film (K⁻¹) for ideal gases, ν (m²/s).
  • Ra = Gr·Pr, Nu = C·Raⁿ — general correlation; properties at the film temperature.
  • Nu = 0.59·Ra^(1/4) (10⁴–10⁹), Nu = 0.10·Ra^(1/3) (10⁹–10¹³) — vertical plate, L = height.
  • Nu = 0.53·Ra^(1/4) (10⁴–10⁹) — horizontal cylinder, L = D.
  • Gr/Re² — ≪ 1 forced, ≈ 1 mixed, ≫ 1 natural convection.

Heat Transfer with Phase Change: Boiling

  • q″ = h·(T_s − T_sat) = h·ΔT_e — boiling heat flux; ΔT_e excess temperature (K).
  • q″ = μ_l·h_fg·[g·(ρ_l − ρ_v)/σ]^(1/2)·[c_pl·ΔT_e/(C_sf·h_fg·Pr_lⁿ)]³ — Rohsenow nucleate boiling; σ surface tension (N/m), C_sf from data book, n = 1 for water.
  • q″_max = 0.149·h_fg·ρ_v·[σ·g·(ρ_l − ρ_v)/ρ_v²]^(1/4) — critical heat flux (large horizontal heater).
  • ṁ_v = q/h_fg — vapour generation (kg/s); h_fg latent heat (J/kg).

Film and Dropwise Condensation, Nusselt Theory

  • h̄ = 0.943·[ρ_l·(ρ_l − ρ_v)·g·h′_fg·k_l³/(μ_l·L·(T_sat − T_s))]^(1/4) — laminar film, vertical plate or tube of height L.
  • h̄ = 0.725·[ρ_l·(ρ_l − ρ_v)·g·h′_fg·k_l³/(μ_l·D·(T_sat − T_s))]^(1/4) — horizontal tube of diameter D.
  • h′_fg = h_fg + 0.68·c_pl·(T_sat − T_s) — modified latent heat (subcooling).
  • h̄_N = h̄₁·N^(−1/4) — vertical column of N horizontal tubes.
  • Re_δ = 4·ṁ/(μ_l·b) — film Reynolds number; laminar below about 1800.

Radiation Laws: Stefan-Boltzmann, Kirchhoff and Wien

  • E_b = σ·T⁴ — black-body emissive power (W/m²); σ = 5.67 × 10⁻⁸ W/m²·K⁴, T absolute (K).
  • E = ε·σ·T⁴ — gray surface; ε emissivity.
  • λ_max·T = 2898 μm·K — Wien's displacement law.
  • α + ρ + τ = 1 — radiative properties; opaque τ = 0.
  • ε_λ = α_λ — Kirchhoff's law; total ε = α for a gray surface.
  • q = ε₁·σ·A₁·(T₁⁴ − T_sur⁴) — small body in large surroundings.
  • h_r = ε·σ·(T₁² + T_sur²)·(T₁ + T_sur) — radiation heat transfer coefficient.

View Factors and Radiation Exchange Between Surfaces

  • A_i·F_ij = A_j·F_ji — reciprocity.
  • Σ_j F_ij = 1 — summation over all surfaces of an enclosure, including F_ii.
  • q₁₂ = σ·(T₁⁴ − T₂⁴)/[(1 − ε₁)/(ε₁·A₁) + 1/(A₁·F₁₂) + (1 − ε₂)/(ε₂·A₂)] — two-surface gray enclosure.
  • q″ = σ·(T₁⁴ − T₂⁴)/(1/ε₁ + 1/ε₂ − 1) — infinite parallel plates.
  • q = σ·A₁·(T₁⁴ − T₂⁴)/[1/ε₁ + ((1 − ε₂)/ε₂)·(r₁/r₂)] — long concentric cylinders (use (r₁/r₂)² for spheres).
  • F₁₂ = [Σcrossed − Σuncrossed]/(2·L₁) — Hottel crossed-strings (2-D).

Overall Heat Transfer Coefficient and Fouling Factors

  • 1/(U·A) = ΣR — overall coefficient U (W/m²·K) based on area A.
  • 1/U = 1/h₁ + R_f1 + L/k + R_f2 + 1/h₂ — plane or thin wall; R_f fouling resistance (m²·K/W).
  • 1/U_o = d_o/(h_i·d_i) + R_fi·d_o/d_i + d_o·ln(d_o/d_i)/(2k) + R_fo + 1/h_o — tube, outside-area basis.
  • U_o·A_o = U_i·A_i — change of basis.
  • R_f = 1/U_dirty − 1/U_clean — fouling from measurements.

LMTD Method for Double-Pipe and Shell-and-Tube Exchangers

  • q = ṁ_h·c_ph·(T_h,in − T_h,out) = ṁ_c·c_pc·(T_c,out − T_c,in) — energy balance.
  • ΔT_lm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) — log mean temperature difference; ΔT₁, ΔT₂ end differences (K).
  • Counterflow ΔT₁ = T_h,in − T_c,out, ΔT₂ = T_h,out − T_c,in; parallel ΔT₁ = T_h,in − T_c,in, ΔT₂ = T_h,out − T_c,out.
  • q = U·A·F·ΔT_lm,cf — multipass exchangers; F correction factor from P and R.
  • P = (t₂ − t₁)/(T₁ − t₁), R = (T₁ − T₂)/(t₂ − t₁) — t tube side, T shell side.

Effectiveness-NTU Method

  • C = ṁ·c_p, C_r = C_min/C_max — heat capacity rates (W/K).
  • q_max = C_min·(T_h,in − T_c,in), ε = q/q_max — effectiveness.
  • NTU = U·A/C_min — number of transfer units.
  • ε = [1 − exp(−NTU·(1 − C_r))]/[1 − C_r·exp(−NTU·(1 − C_r))] — counterflow (C_r < 1); ε = NTU/(1 + NTU) for C_r = 1.
  • ε = [1 − exp(−NTU·(1 + C_r))]/(1 + C_r) — parallel flow.
  • ε = 1 − exp(−NTU) — any arrangement with C_r = 0 (condensing or boiling stream).

Evaporators: Single and Multiple Effect Evaporation

  • F·x_F = P·x_P, V = F − P — solute and total balances; F feed, P product, V vapour (kg/h), x solids mass fraction.
  • S·λ_S = F·c_pF·(T₁ − T_F) + V·λ_V — single-effect enthalpy balance (negligible BPR and losses); S steam (kg/h), λ latent heats (kJ/kg).
  • q = U·A·(T_S − T₁) — calandria heat transfer; T_S steam saturation temperature, T₁ boiling temperature.
  • Economy = V/S — kg water evaporated per kg steam; about 0.8N for N effects in practice.
  • BPR = T_b,solution − T_sat,water — boiling-point rise at the same pressure (Dühring's rule gives T_b linear in T_sat).
  • ΔT_i ∝ 1/U_i — temperature-drop distribution in a multiple effect with equal areas and duties.