Chemical Engineering Thermodynamics — formula sheet

Chemical Engineering · GATE CH · SI units. Drafted with Aria, checked by the AiCanCode.org team.

First law for closed and open systems

  • ΔU = Q − W — Closed system; ΔU change in internal energy (J); Q heat added to the system (J); W work done by the system (J).
  • W = ∫P dV — Reversible boundary work (J); P pressure (Pa); V volume (m³).
  • H = U + PV — Enthalpy (J); at constant pressure with only PV work, Q = ΔH.
  • Q̇ − Ẇs = ṁ·[Δh + Δ(c²/2) + g·Δz] — Steady flow, one stream; Q̇ heat rate (W); Ẇs shaft power out (W); ṁ mass flow (kg/s); h specific enthalpy (J/kg); c velocity (m/s); z elevation (m).
  • dU = Cv dT, dH = Cp dT, Cp − Cv = R — Ideal gas; Cv, Cp molar heat capacities (J/mol·K); R = 8.314 J/(mol·K).
  • T_final = γ·T_line — Evacuated, insulated rigid tank filled with an ideal gas (constant heat capacities); γ = Cp/Cv.

PVT behaviour, virial and cubic equations of state

  • Z = P·V/(R·T) — Compressibility factor (dimensionless); V molar volume (m³/mol); T (K).
  • Z = 1 + B·P/(R·T) — Two-term virial equation, gases at low to moderate pressure; B second virial coefficient (m³/mol), a function of T only.
  • P = R·T/(V − b) − a/V² — van der Waals; a (Pa·m⁶/mol²); b (m³/mol).
  • a = 27·R²·Tc²/(64·Pc), b = R·Tc/(8·Pc) — van der Waals constants from critical temperature Tc (K) and pressure Pc (Pa); Zc = 3/8.
  • P = R·T/(V − b) − a·α/(V² + 2·b·V − b²) — Peng-Robinson; α a function of Tr and acentric factor ω.
  • ω = −1 − log₁₀(Pr_sat) at Tr = 0.7 — Acentric factor; Tr = T/Tc, Pr = P/Pc.

Second law, entropy and Carnot cycle

  • dS = δQ_rev/T — Entropy change (J/K); δQ_rev reversible heat (J); T absolute temperature (K).
  • ΔS_total = ΔS_system + ΔS_surroundings ≥ 0 — Second law; equality only for reversible processes.
  • η = 1 − T_C/T_H — Carnot engine efficiency; T_C, T_H cold and hot reservoir temperatures (K).
  • ΔS = Cp·ln(T₂/T₁) − R·ln(P₂/P₁) — Ideal gas, molar (J/mol·K), constant Cp.
  • ΔS = m·c·ln(T₂/T₁) — Incompressible solid or liquid; m mass (kg); c specific heat (J/kg·K).
  • W_lost = T₀·S_gen — Lost work (J); T₀ surroundings temperature (K); S_gen entropy generated (J/K).

Thermodynamic property relations and Maxwell relations

  • dU = T dS − P dV, dH = T dS + V dP, dA = −S dT − P dV, dG = −S dT + V dP — Fundamental relations, molar properties, constant composition.
  • (∂S/∂V)_T = (∂P/∂T)_V, (∂S/∂P)_T = −(∂V/∂T)_P — Maxwell relations from A and G.
  • (∂U/∂V)_T = T(∂P/∂T)_V − P — Energy equation; equals a/V² for a van der Waals gas, zero for an ideal gas.
  • dH = Cp dT + [V − T(∂V/∂T)_P] dP — Enthalpy of a real fluid in terms of T and P.
  • μ_JT = (∂T/∂P)_H = [T(∂V/∂T)_P − V]/Cp — Joule-Thomson coefficient (K/Pa).
  • ln(P₂/P₁) = −(ΔH_vap/R)·(1/T₂ − 1/T₁) — Clausius-Clapeyron; ΔH_vap latent heat (J/mol); ideal vapour, negligible liquid volume.

Residual properties and generalised correlations

  • M^R = M − M^ig — Residual property at the same T and P (M = V, H, S, G …).
  • G^R/RT = ∫₀^P (Z − 1) dP/P — Constant T; equals ln φ for a pure species.
  • H^R/RT = −T∫₀^P (∂Z/∂T)_P dP/P, S^R/R = H^R/RT − G^R/RT — Residual enthalpy and entropy.
  • Z = 1 + (B⁰ + ω·B¹)·Pr/Tr — Pitzer virial correlation; B⁰ = 0.083 − 0.422/Tr^1.6, B¹ = 0.139 − 0.172/Tr^4.2.
  • H^R/(R·Tc) = Pr·[B⁰ − Tr·dB⁰/dTr + ω·(B¹ − Tr·dB¹/dTr)] — With dB⁰/dTr = 0.675/Tr^2.6, dB¹/dTr = 0.722/Tr^5.2.
  • Z = Z⁰ + ω·Z¹ — Lee-Kesler; Z⁰ and Z¹ from tables in a data book.

Refrigeration and liquefaction cycles

  • COP_R = Q_C/W, COP_HP = Q_H/W = COP_R + 1 — Q_C heat removed from cold space (J); Q_H heat rejected (J); W work input (J).
  • COP_Carnot = T_C/(T_H − T_C) — Reversed Carnot refrigerator; temperatures in K.
  • COP = (h₁ − h₄)/(h₂ − h₁), h₄ = h₃ — Vapour compression; h specific enthalpy (kJ/kg) at evaporator exit (1), compressor exit (2), condenser exit (3), valve exit (4).
  • y = (h_LP − h_HP)/(h_LP − h_f) — Linde liquid yield; h_HP high-pressure feed, h_LP returning low-pressure gas (warm end), h_f saturated liquid.

Partial molar properties and Gibbs-Duhem equation

  • M̄ᵢ = [∂(nM)/∂nᵢ]_{T,P,nⱼ} — Partial molar property of species i.
  • M = Σ xᵢ·M̄ᵢ — Summability.
  • Σ xᵢ dM̄ᵢ = 0 — Gibbs-Duhem at constant T and P.
  • M̄₁ = M + x₂·dM/dx₁, M̄₂ = M − x₁·dM/dx₁ — Binary mixtures (tangent-intercept).
  • d(nG) = −(nS) dT + (nV) dP + Σ μᵢ dnᵢ — Open phase; μᵢ = Ḡᵢ chemical potential (J/mol).

Fugacity and fugacity coefficient of pure species and mixtures

  • dGᵢ = R·T·d ln fᵢ, φᵢ = fᵢ/P — Definition at constant T; fᵢ fugacity (Pa); φᵢ → 1 as P → 0.
  • ln φ = B·P/(R·T) — Two-term virial gas.
  • fᵢ^l = φᵢ^sat·Pᵢ^sat·exp[Vᵢ^l·(P − Pᵢ^sat)/(R·T)] — Compressed liquid with Poynting factor; Vᵢ^l liquid molar volume (m³/mol).
  • f̂ᵢ = φ̂ᵢ·yᵢ·P — Species in a gas mixture; φ̂ᵢ fugacity coefficient in solution.
  • ln φ̂₁ = (P/RT)·(B₁₁ + y₂²·δ₁₂), δ₁₂ = 2B₁₂ − B₁₁ − B₂₂ — Binary virial mixture.

Ideal solutions, Lewis-Randall rule and excess properties

  • f̂ᵢ^id = xᵢ·fᵢ — Lewis-Randall rule; fᵢ pure-species fugacity at the mixture T and P.
  • ΔH_mix^id = 0, ΔV_mix^id = 0, ΔS_mix^id = −R·Σ xᵢ ln xᵢ, ΔG_mix^id = R·T·Σ xᵢ ln xᵢ — Ideal-solution mixing functions (per mole of mixture).
  • M^E = M − M^id — Excess property; H^E = ΔH_mix and V^E = ΔV_mix.
  • γᵢ = f̂ᵢ/(xᵢ·fᵢ) — Activity coefficient.
  • G^E/(R·T) = Σ xᵢ·ln γᵢ — ln γᵢ is the partial molar property of G^E/RT.

Activity coefficient models: Margules, van Laar, Wilson, NRTL

  • G^E/RT = A·x₁x₂; ln γ₁ = A·x₂², ln γ₂ = A·x₁² — Two-suffix Margules (A dimensionless).
  • ln γ₁ = x₂²·[A₁₂ + 2(A₂₁ − A₁₂)·x₁], ln γ₂ = x₁²·[A₂₁ + 2(A₁₂ − A₂₁)·x₂] — Three-suffix Margules; ln γ₁^∞ = A₁₂, ln γ₂^∞ = A₂₁.
  • ln γ₁ = A′₁₂·(1 + A′₁₂·x₁/(A′₂₁·x₂))^(−2), ln γ₂ = A′₂₁·(1 + A′₂₁·x₂/(A′₁₂·x₁))^(−2) — van Laar.
  • ln γ₁ = −ln(x₁ + x₂·Λ₁₂) + x₂·[Λ₁₂/(x₁ + x₂·Λ₁₂) − Λ₂₁/(x₂ + x₁·Λ₂₁)] — Wilson; cannot predict liquid-liquid splitting.
  • ln γ₁ = x₂²·[τ₂₁·(G₂₁/(x₁ + x₂·G₂₁))² + τ₁₂·G₁₂/(x₂ + x₁·G₁₂)²], Gᵢⱼ = exp(−α·τᵢⱼ) — NRTL; α non-randomness parameter.

Phase rule and criteria for phase equilibrium

  • μᵢ^α = μᵢ^β, equivalently f̂ᵢ^α = f̂ᵢ^β — Phase equilibrium for every species, at equal T and P.
  • F = 2 − π + N — Gibbs phase rule; F degrees of freedom (intensive); π number of phases; N number of species.
  • F = 2 − π + N − r − s — With r independent reactions and s special constraints.
  • d²(ΔG_mix/RT)/dx₁² > 0 — Stability of a single liquid phase (binary, constant T and P).

Vapour-liquid equilibrium: bubble and dew point calculations

  • yᵢ·P = xᵢ·Pᵢ^sat — Raoult's law; P total pressure (kPa); Pᵢ^sat vapour pressure (kPa).
  • P_bubble = Σ xᵢ·Pᵢ^sat, 1/P_dew = Σ yᵢ/Pᵢ^sat — Raoult's law bubble and dew pressures.
  • α₁₂ = P₁^sat/P₂^sat — Relative volatility (Raoult).
  • ln Pᵢ^sat = A − B/(T + C) — Antoine equation; constants from a data book in its stated units.

Modified Raoult's law and azeotropes

  • yᵢ·P = xᵢ·γᵢ·Pᵢ^sat — Modified Raoult's law (low pressure, non-ideal liquid).
  • P = Σ xᵢ·γᵢ·Pᵢ^sat, 1/P = Σ yᵢ/(γᵢ·Pᵢ^sat) — Bubble and dew pressures.
  • γ₁·P₁^sat = γ₂·P₂^sat, γᵢ = P/Pᵢ^sat — At an azeotrope (x = y, α₁₂ = 1).
  • α₁₂(x₁→0) = γ₁^∞·P₁^sat/P₂^sat, α₁₂(x₁→1) = P₁^sat/(γ₂^∞·P₂^sat) — Azeotrope exists if one is above 1 and the other below 1.

Flash calculations

  • Kᵢ = yᵢ/xᵢ — K-value; equals Pᵢ^sat/P under Raoult's law.
  • Σ zᵢ·(Kᵢ − 1)/[1 + V·(Kᵢ − 1)] = 0 — Rachford-Rice; V vapour fraction of feed; zᵢ feed mole fraction.
  • xᵢ = zᵢ/[1 + V·(Kᵢ − 1)], yᵢ = Kᵢ·xᵢ — Phase compositions.
  • Σ zᵢ·Kᵢ > 1 and Σ zᵢ/Kᵢ > 1 — Feed is two-phase.
  • V/F = (z₁ − x₁)/(y₁ − x₁) — Lever rule (binary).

Liquid-liquid and solid-liquid equilibrium

  • xᵢ^α·γᵢ^α = xᵢ^β·γᵢ^β — LLE: equal activities of each species in both liquid phases.
  • K_D = x_solute^E/x_solute^R — Distribution coefficient between extract (E) and raffinate (R).
  • ln(xᵢ·γᵢ) = −(ΔH_fus,ᵢ/R)·(1/T − 1/T_m,ᵢ) — SLE for pure solid i (ΔCp neglected); ΔH_fus heat of fusion (J/mol); T_m melting point (K); γᵢ = 1 gives ideal solubility.

Chemical reaction equilibrium and equilibrium constant

  • nᵢ = nᵢ₀ + νᵢ·ε, yᵢ = (nᵢ₀ + νᵢ·ε)/(n₀ + ν·ε) — Extent of reaction ε (mol); ν = Σνᵢ.
  • K = exp(−ΔG°/(R·T)), ΔG° = Σ νᵢ·ΔG°f,ᵢ — K dimensionless, depends on T only.
  • K = Π aᵢ^νᵢ = Π (f̂ᵢ/fᵢ°)^νᵢ — Activities; pure solids and liquids have aᵢ = 1.
  • Π yᵢ^νᵢ = K·(P/P°)^(−ν) — Ideal-gas reactions; P° = 1 bar.

Effect of temperature and pressure on equilibrium conversion

  • d ln K/dT = ΔH°/(R·T²) — van't Hoff; ΔH° standard heat of reaction (J/mol).
  • ln(K₂/K₁) = −(ΔH°/R)·(1/T₂ − 1/T₁) — Constant ΔH° (shortcut).
  • ΔH°(T) = ΔH°(T₀) + ∫ΔCp° dT, ΔCp° = Σ νᵢ·Cp,ᵢ° — Temperature dependence of heat of reaction.
  • Π yᵢ^νᵢ = K·(P/P°)^(−ν) — For ν < 0 higher pressure raises conversion; for ν > 0 lower pressure (or inert dilution) raises it.

Multireaction equilibria

  • nᵢ = nᵢ₀ + Σⱼ νᵢ,ⱼ·εⱼ — One extent εⱼ per independent reaction j.
  • Πᵢ yᵢ^νᵢ,ⱼ = Kⱼ·(P/P°)^(−νⱼ) — One equilibrium equation per independent reaction (ideal gases).
  • K₃ = K₁·K₂ — When reaction 3 = reaction 1 + reaction 2.
  • Number of independent reactions = N_species − rank(element matrix) — Usually species minus elements.
  • ΔG°f,ᵢ + R·T·ln(yᵢ·P/P°) + Σₖ λₖ·aᵢₖ = 0 — Gibbs minimisation (ideal gas) with element balances; λₖ Lagrange multipliers; aᵢₖ atoms of element k in species i.