Thermodynamics and Heat Transfer — formula sheet

Automobile Engineering · GATE ME · SI units. Drafted with Aria, checked by the AiCanCode.org team.

Systems, properties, work and heat

  • W = ∫ P dV — boundary work by the system (J); P in Pa, V in m³; quasi-static processes only. Work by the system positive, heat into the system positive.
  • W = P(V₂ − V₁) — constant pressure; W = 0 at constant volume and in free expansion.
  • W = P₁V₁ ln(V₂/V₁) = mRT ln(P₁/P₂) — isothermal ideal gas; R: specific gas constant (J/kg·K; air 287).
  • W = (P₁V₁ − P₂V₂)/(n − 1) — polytropic PVⁿ = C, n ≠ 1.
  • W_shaft = 2πNT/60 (W), W_el = VIt (J), W_spring = ½k(x₂² − x₁²) (J) — N in rpm, T in N·m, k in N/m.
  • Q = m c ΔT — sensible heat; c in J/kg·K.

Properties of pure substances and steam tables

  • x = m_g/(m_f + m_g) — dryness fraction (wet region only).
  • v = v_f + x v_fg, h = h_f + x h_fg, s = s_f + x s_fg — wet mixture; f: saturated liquid, g: saturated vapour, fg = g − f.
  • h = u + Pv — kJ/kg with P in kPa, v in m³/kg.
  • h ≈ h_f(T) + v_f(P − P_sat(T)) — compressed liquid.
  • Phase test: T < T_sat(P) compressed liquid; T > T_sat(P) superheated.

First law for closed systems and steady-flow devices

  • Q − W = ΔU — closed, stationary system; ∮δQ = ∮δW for a cycle.
  • ΔU = m c_v ΔT, ΔH = m c_p ΔT, c_p − c_v = R, γ = c_p/c_v — ideal gas, any process.
  • Q̇ − Ẇ = ṁ[(h₂ − h₁) + (V₂² − V₁²)/2 + g(z₂ − z₁)] — SFEE; Ẇ: shaft power out; V²/2 in J/kg.
  • V₂ = √(2(h₁ − h₂) + V₁²) — adiabatic nozzle, h in J/kg.
  • h₁ = h₂ — throttling; T₂ = γ T_line — filling an evacuated insulated tank with ideal gas.

Second law, heat engines, Carnot cycle and entropy

  • η = 1 − Q_L/Q_H; η_Carnot = 1 − T_L/T_H — T in K.
  • COP_R = T_L/(T_H − T_L), COP_HP = T_H/(T_H − T_L) (reversible); COP_HP = COP_R + 1.
  • ∮ δQ/T ≤ 0 — Clausius inequality (> 0 impossible).
  • dS = (δQ/T)_rev; ΔS = Q/T for a reservoir or reversible isothermal process.
  • ΔS = m c ln(T₂/T₁) — solid or liquid.
  • Δs = c_p ln(T₂/T₁) − R ln(P₂/P₁) — ideal gas.
  • S_gen = ΔS_sys + ΔS_surr ≥ 0.

Availability, irreversibility and exergy

  • φ = (u − u₀) + P₀(v − v₀) − T₀(s − s₀) + V²/2 + gz — closed-system specific exergy; subscript 0: dead state.
  • ψ = (h − h₀) − T₀(s − s₀) + V²/2 + gz — flow exergy.
  • X_Q = Q(1 − T₀/T) — exergy of heat at temperature T.
  • I = T₀ S_gen — irreversibility (Gouy–Stodola).
  • W_u = W − P₀(V₂ − V₁) — useful work of a closed system.
  • η_II = W_u/W_rev (engines), W_rev,in/W_in (compressors), COP/COP_rev (refrigerators).

Ideal gas mixtures and thermodynamic relations

  • PV = mRT = n R_u T — R_u = 8.314 kJ/kmol·K; R = R_u/M.
  • y_i = n_i/n, P_i = y_i P (Dalton), V_i = y_i V (Amagat).
  • M = Σ y_i M_i; c_p = Σ mf_i c_p,i — mf: mass fraction.
  • ΔS_mix = −R_u Σ n_i ln y_i — ideal gases at the same T and P.
  • T ds = du + P dv, T ds = dh − v dP — Gibbs equations.
  • (∂T/∂v)_s = −(∂P/∂s)_v, (∂T/∂P)_s = (∂v/∂s)_P, (∂P/∂T)_v = (∂s/∂v)_T, (∂v/∂T)_P = −(∂s/∂P)_T — Maxwell relations.
  • (dP/dT)_sat = h_fg/(T v_fg) — Clapeyron equation.
  • c_p − c_v = T v β²/κ_T; μ_JT = (∂T/∂P)_h.

Rankine cycle with reheat and regeneration

  • w_P = v_f(P₂ − P₁) — pump work, kJ/kg (P in kPa).
  • η = (w_T − w_P)/q_in — reheat: w_T = (h₃ − h₄) + (h₅ − h₆), q_in = (h₃ − h₂) + (h₅ − h₄).
  • x = (s − s_f)/s_fg — quality after isentropic expansion.
  • y = (h_f,heater − h_fw,in)/(h_bleed − h_fw,in) — fraction bled to an open feedwater heater.
  • SSC = 3600/w_net — kg/kWh, w_net in kJ/kg.

Brayton cycle and gas turbine improvements

  • T₂/T₁ = T₃/T₄ = r_p^((γ−1)/γ) — isentropic; r_p = P₂/P₁.
  • η = 1 − 1/r_p^((γ−1)/γ) — ideal Brayton.
  • η = 1 − (T₄ − T₁)/(T₃ − T₂) — any constant-c_p cycle of this form.
  • r_p,opt = (T₃/T₁)^(γ/(2(γ−1))), w_net,max = c_p(√T₃ − √T₁)² — maximum net work.
  • η_C = (T₂s − T₁)/(T₂ − T₁), η_T = (T₃ − T₄)/(T₃ − T₄s).
  • ε = (T_x − T₂)/(T₄ − T₂) — regenerator effectiveness.

Vapour compression refrigeration and refrigerants

  • RE = h₁ − h₄, h₄ = h₃ — refrigerating effect; 1: compressor inlet, 3: condenser exit.
  • w_C = h₂ − h₁; COP = (h₁ − h₄)/(h₂ − h₁).
  • ṁ = Q̇_L/(h₁ − h₄); Ẇ = ṁ(h₂ − h₁).
  • η_C = (h₂s − h₁)/(h₂ − h₁); 1 TR = 3.517 kW.

Psychrometry and vehicle air conditioning

  • φ = p_v/p_sat(T_db) — relative humidity.
  • ω = 0.622 p_v/(P − p_v) — specific humidity, kg/kg dry air.
  • h = 1.005 t + ω(2501 + 1.88 t) — kJ/kg dry air, t in °C.
  • DPT = T_sat(p_v).
  • ṁ_w = ṁ_a(ω₁ − ω₂); Q̇ = ṁ_a[(h₁ − h₂) − (ω₁ − ω₂)h_f] — cooling coil.
  • BF = (T₂ − T_ADP)/(T₁ − T_ADP); SHF = Q̇_s/(Q̇_s + Q̇_L).

One-dimensional steady conduction and thermal resistance

  • Q = −kA dT/dx — Fourier's law.
  • R = L/(kA) (wall), R = ln(r₂/r₁)/(2πkL) (cylinder), R = (r₂ − r₁)/(4πk r₁r₂) (sphere), R = 1/(hA) (convection) — K/W.
  • Q = ΔT_overall/ΣR; 1/U = 1/h₁ + ΣL/k + 1/h₂ (plane wall).
  • r_c = k/h (cylinder), 2k/h (sphere) — critical radius of insulation.

Heat transfer from fins

  • m = √(hP/(kA_c)); pin fin m = √(4h/(kD)).
  • Q = √(hPkA_c) θ_b tanh(mL) — insulated tip; Q = √(hPkA_c) θ_b — infinitely long fin; θ_b = T_b − T_∞.
  • θ/θ_b = cosh m(L − x)/cosh mL — insulated tip.
  • L_c = L + A_c/P — corrected length for a convective tip.
  • η_f = tanh(mL_c)/(mL_c); ε_f = Q_fin/(hA_cθ_b), long fin ε_f = √(kP/(hA_c)).

Unsteady conduction: lumped capacitance and Heisler charts

  • Bi = hL_c/k — lumped analysis valid for Bi < 0.1 with L_c = V/A_s (sphere r₀/3, long cylinder r₀/2, slab half-thickness).
  • (T − T_∞)/(T_i − T_∞) = exp(−t/τ), τ = ρcV/(hA_s).
  • Fo = αt/L_c², α = k/(ρc); exp(−t/τ) = exp(−Bi·Fo).
  • (T − T_s)/(T_i − T_s) = erf(x/(2√(αt))) — semi-infinite solid, step change in surface temperature.

Forced convection: laminar and turbulent correlations

  • Re = VL/ν, Pr = μc_p/k, Nu = hL/k_fluid, St = Nu/(Re·Pr).
  • Nu_x = 0.332 Re_x^(1/2) Pr^(1/3), Nu_L = 0.664 Re_L^(1/2) Pr^(1/3) — laminar flat plate, Re < 5 × 10⁵.
  • Nu_L = (0.037 Re_L^(4/5) − 871) Pr^(1/3) — mixed laminar–turbulent flat plate.
  • Nu_D = 3.66 (constant T_s), 4.36 (constant q″) — laminar fully developed pipe flow.
  • Nu_D = 0.023 Re^0.8 Pr^n — Dittus–Boelter, n = 0.4 heating, 0.3 cooling; Re > 10⁴.
  • (T_s − T_out)/(T_s − T_in) = exp(−hPL/(ṁc_p)) — tube with constant wall temperature.

Natural convection

  • Gr = gβΔT L³/ν², Ra = Gr·Pr, β = 1/T_f (ideal gas, K).
  • Nu = 0.59 Ra^(1/4) (10⁴–10⁹), Nu = 0.10 Ra^(1/3) (10⁹–10¹³) — vertical plate, L = height.
  • Nu = 0.54 Ra^(1/4) (10⁴–10⁷), 0.15 Ra^(1/3) (10⁷–10¹¹) — hot plate facing up; Nu = 0.27 Ra^(1/4) — hot plate facing down; L_c = A/P.
  • Gr/Re² — ≪ 1 forced dominates, ≫ 1 natural dominates.

Radiation: black body, view factors and radiosity networks

  • E_b = σT⁴ — σ = 5.67 × 10⁻⁸ W/m²·K⁴; T in K.
  • λ_max T = 2898 μm·K — Wien's law.
  • α + ρ + τ = 1; ε = α (Kirchhoff, gray surfaces).
  • A₁F₁₂ = A₂F₂₁; ΣF_ij = 1; F_ii = 0 for flat or convex surfaces.
  • Q₁₂ = σ(T₁⁴ − T₂⁴)/[(1 − ε₁)/(ε₁A₁) + 1/(A₁F₁₂) + (1 − ε₂)/(ε₂A₂)] — two-surface enclosure.
  • q = σ(T₁⁴ − T₂⁴)/(1/ε₁ + 1/ε₂ − 1) — large parallel plates; Q = ε₁σA₁(T₁⁴ − T₂⁴) — small body in large enclosure.
  • With N shields of the same ε as the plates, heat transfer falls to 1/(N + 1).

Heat exchangers: LMTD and effectiveness-NTU methods

  • Q = UAΔT_lm, ΔT_lm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) — parallel: ΔT₁ = T_h,in − T_c,in; counterflow: ΔT₁ = T_h,in − T_c,out.
  • C = ṁc_p, C_r = C_min/C_max, NTU = UA/C_min, Q_max = C_min(T_h,in − T_c,in), ε = Q/Q_max.
  • ε = [1 − exp(−NTU(1 + C_r))]/(1 + C_r) — parallel flow.
  • ε = [1 − exp(−NTU(1 − C_r))]/[1 − C_r exp(−NTU(1 − C_r))] — counterflow; ε = NTU/(1 + NTU) when C_r = 1.
  • ε = 1 − exp(−NTU) — C_r = 0 (condenser, evaporator).

Engine cooling systems and radiator heat transfer

  • Q̇ = ṁ c_p ΔT — coolant or air stream; ṁ in kg/s, c_p in J/kg·K, Q̇ in W.
  • ITD = T_coolant,in − T_air,in; Q̇ = ε C_min ITD.
  • ε ≈ 1 − exp[(NTU^0.22/C_r)(exp(−C_r NTU^0.78) − 1)] — cross-flow, both fluids unmixed.
  • 1/(UA) = 1/(h_c A_c) + R_wall + 1/(η_o h_a A_a) — air side usually dominates.