Fluid Mechanics and Turbomachinery — formula sheet

Automobile Engineering · GATE ME · SI units. Drafted with Aria, checked by the AiCanCode.org team.

Fluid properties

  • τ = μ·(du/dy) — Newton's law of viscosity; τ shear stress (Pa), μ dynamic viscosity (Pa·s), du/dy velocity gradient (s⁻¹); Newtonian fluids.
  • ν = μ/ρ — kinematic viscosity (m²/s); ρ density (kg/m³). 1 poise = 0.1 Pa·s; 1 stokes = 10⁻⁴ m²/s.
  • Δp = 2σ/R (drop), Δp = 4σ/R (soap bubble), Δp = σ/R (liquid jet) — excess internal pressure (Pa); σ surface tension (N/m), R radius (m).
  • h = 4σ·cosθ/(ρ·g·d) — capillary rise (m) in a tube of bore d (m); θ contact angle.
  • K = −dp/(dV/V) — bulk modulus (Pa); compressibility β = 1/K; speed of sound c = √(K/ρ) (m/s).

Fluid statics, manometry and forces on submerged surfaces

  • p = p₀ + ρ·g·h — pressure at depth h (m) below a free surface at pressure p₀ (Pa); static fluid of constant density.
  • p_A − p_B = g·(ρ_m − ρ)·x — differential U-tube manometer, A and B at the same level; ρ_m gauge-liquid density, x deflection (m).
  • F = ρ·g·h̄·A — hydrostatic force (N) on a plane area A (m²) with centroid depth h̄ (m).
  • h_cp = h̄ + I_G·sin²θ/(A·h̄) — depth of centre of pressure (m); I_G second moment of area about the centroidal axis (m⁴); θ inclination of the plane to the free surface.
  • F_H = ρ·g·h̄_p·A_p, F_V = ρ·g·V_above — curved surface: horizontal component on the vertical projection; vertical component = weight of liquid above.

Buoyancy and stability of floating bodies

  • F_B = ρ_f·g·V_d — buoyant force (N); ρ_f fluid density (kg/m³), V_d displaced volume (m³); acts through the centre of buoyancy B.
  • BM = I/V_d — metacentric radius (m); I second moment of the waterline area about the tilt axis (m⁴).
  • GM = KB + BM − KG — metacentric height (m); floating body stable if GM > 0. Submerged body stable if B is above G.
  • GM = w·x/(W·tanθ) — inclining experiment; w moved weight (N), x shift (m), W total weight (N), θ heel angle.
  • T = 2π·k/√(g·GM) — period of roll (s); k radius of gyration (m).

Kinematics: streamlines, stream function and velocity potential

  • dx/u = dy/v = dz/w — streamline equation; u, v, w velocity components (m/s).
  • a_x = ∂u/∂t + u·∂u/∂x + v·∂u/∂y + w·∂u/∂z — local plus convective acceleration (m/s²).
  • ∂u/∂x + ∂v/∂y + ∂w/∂z = 0 — continuity, incompressible flow.
  • ω_z = ½·(∂v/∂x − ∂u/∂y) — rotation (rad/s); irrotational if zero; vorticity = 2ω.
  • u = ∂ψ/∂y, v = −∂ψ/∂x — stream function ψ (m²/s); exists for 2-D incompressible flow; ψ₂ − ψ₁ = flow per unit depth (m²/s).
  • u = ∂φ/∂x, v = ∂φ/∂y — velocity potential φ (m²/s); exists only for irrotational flow; φ and ψ lines are orthogonal.

Control volume analysis: continuity and momentum equations

  • ṁ = ρ₁·A₁·V₁ = ρ₂·A₂·V₂ — steady continuity; ṁ (kg/s), A (m²), V (m/s); Q = A·V (m³/s) for incompressible flow.
  • ΣF = ṁ·(V_out − V_in) — steady momentum equation (vector; write x and y separately); ΣF is the total force on the fluid (N), including gauge-pressure forces.
  • F = ρ·A·V² — force of a jet on a fixed flat plate normal to it (N).
  • T = ṁ·(r₂·V_w2 − r₁·V_w1) — moment of momentum; torque on the fluid (N·m); r radius (m), V_w tangential velocity (m/s).

Bernoulli's equation and flow measurement

  • p₁/(ρg) + V₁²/(2g) + z₁ = p₂/(ρg) + V₂²/(2g) + z₂ — Bernoulli; steady, incompressible, inviscid flow along a streamline; each term in m.
  • p₁/(ρg) + V₁²/(2g) + z₁ + H_p = p₂/(ρg) + V₂²/(2g) + z₂ + H_t + h_L — energy equation with pump head H_p, turbine head H_t and head loss h_L (m).
  • Q = C_d·A₁·A₂·√(2gh)/√(A₁² − A₂²) — venturi or orifice meter (m³/s); h piezometric head difference (m of flowing fluid).
  • h = x·(S_m/S − 1) — head from a differential manometer reading x (m); S_m, S relative densities of gauge and flowing liquids.
  • V = √(2·(p₀ − p)/ρ) — Pitot-static tube velocity (m/s); V = √(2gH) Torricelli jet from head H (m).

Dimensional analysis and similitude

  • Number of π groups = n − m — n variables, m fundamental dimensions (Buckingham π theorem).
  • Re = ρVL/μ, Fr = V/√(gL), Eu = Δp/(ρV²), We = ρV²L/σ, Ma = V/c — dimensionless numbers; L characteristic length (m).
  • V_m·L_m/ν_m = V_p·L_p/ν_p — Reynolds model law (enclosed flows); subscripts m model, p prototype.
  • V_r = √L_r, Q_r = L_r^2.5, F_r = L_r³ — Froude model law (free-surface flows, same fluid); r = prototype/model ratio.
  • Q/(ND³), gH/(N²D²), P/(ρN³D⁵) — constant for similar turbomachines.

Viscous flow between parallel plates and in pipes

  • Δp = 32·μ·V·L/D² — Hagen–Poiseuille pressure drop (Pa); V mean velocity (m/s), L length (m), D diameter (m); laminar, fully developed, Re < about 2000.
  • Q = π·Δp·D⁴/(128·μ·L) — laminar pipe flow rate (m³/s); u_max = 2V.
  • f = 64/Re — Darcy friction factor, laminar pipe flow.
  • τ_w = Δp·D/(4L) — wall shear stress (Pa); shear varies linearly from zero at the axis.
  • q = (−dp/dx)·h³/(12μ) — flow per unit width (m²/s) between fixed plates a gap h (m) apart; u_max = 1.5V.
  • τ = μ·U/h — Couette flow (one plate moving at U, no pressure gradient).

Turbulent pipe flow, Moody chart and minor losses

  • h_f = f·(L/D)·V²/(2g) — Darcy–Weisbach head loss (m); f Darcy friction factor (= 4 × Fanning f).
  • h_f = 8·f·L·Q²/(π²·g·D⁵) — same in terms of Q (m³/s).
  • f = 0.316/Re^0.25 — Blasius, smooth pipes, 4000 < Re < 10⁵.
  • 1/√f = −2.0·log₁₀(ε/(3.7D) + 2.51/(Re·√f)) — Colebrook; ε absolute roughness (m).
  • h_L = K·V²/(2g) — minor loss (m); sharp entrance K = 0.5, exit K = 1.0.
  • h_L = (V₁ − V₂)²/(2g) — sudden expansion loss (m).
  • D_h = 4A/P — hydraulic diameter (m); A flow area (m²), P wetted perimeter (m).

Pipe networks and flow in series and parallel

  • Δp = f·(L/D)·(ρV²/2) — Darcy–Weisbach pressure drop (Pa).
  • Q₁ = Q₂ = …; H = h₁ + h₂ + … — pipes in series.
  • L/D_e⁵ = Σ(L_i/D_i⁵) — Dupuit equivalent pipe (same f).
  • Q = Q₁ + Q₂ + …; h₁ = h₂ = … — pipes in parallel; Q_i ∝ √(D_i⁵/(f_i·L_i)).
  • ΔQ = −Σ(kQ|Q|)/Σ(2k|Q|) — Hardy Cross loop correction, with h = kQ².
  • h_f = H/3 — condition for maximum power transmission through a pipe (η = 66.7 %).

Boundary layer, drag and lift

  • δ = 5x/√Re_x, C_D = 1.328/√Re_L — laminar flat plate (Re < 5 × 10⁵); δ thickness (m), Re_x = Ux/ν.
  • δ = 0.37x/Re_x^0.2, C_D = 0.074/Re_L^0.2 — turbulent flat plate (5 × 10⁵ < Re_L < 10⁷).
  • C_D = F_D/(0.5·ρ·V²·A) — drag coefficient; F_D drag (N), A reference area (m²) — plan area for plates, frontal area for vehicles.
  • F_L = C_L·0.5·ρ·V²·A — lift (N); P = F_D·V drag power (W).
  • F_D = 3π·μ·V·d — Stokes drag on a sphere (Re < 1); C_D = 24/Re.

Impact of jets and velocity triangles

  • F = ρQ(V₁ − V₂) — force of a jet on a vane in the direction considered (N); V₁, V₂ velocity components entering and leaving in that direction (m/s); the force on the fluid is ρQ(V₂ − V₁).
  • F = ρ·A·(V − u)² — single plate moving at u (m/s); F = ρ·A·V·(V − u) — series of plates on a wheel.
  • V⃗ = u⃗ + V⃗_r — absolute = blade + relative velocity; V_w whirl component, V_f flow component.
  • W = u·(V_w1 ± V_w2) — work per kg on a moving vane (J/kg); + when V_w2 opposes u.
  • η = 2u(V − u)/V² — series of flat plates; maximum 50 % at u = V/2.

Pelton, Francis and Kaplan turbines

  • P = ρgQHη — turbine power output (W); H net head (m), η overall efficiency.
  • W = V_w1·u₁ ± V_w2·u₂, η_h = W/(gH) — Euler turbine equation and hydraulic efficiency.
  • V₁ = C_v·√(2gH) — Pelton jet velocity; ideal optimum u = V₁/2.
  • Q = π·D₁·B₁·V_f1 (Francis), Q = (π/4)·(D_o² − D_b²)·V_f (Kaplan) — runner flow (m³/s).
  • N_s = N·√P/H^(5/4) — turbine specific speed; N (rpm), P (kW), H (m). Approximate ranges: Pelton 10–35 per jet, Francis 50–300, Kaplan 300–1000.

Centrifugal pumps: characteristics and cavitation

  • H = (p₂ − p₁)/(ρg) + (V₂² − V₁²)/(2g) + (z₂ − z₁) — head developed by a pump (m) from flange readings.
  • H_e = V_w2·u₂/g — Euler head with radial entry; V_w2 = u₂ − V_f2/tanβ₂.
  • η_mano = gH_m/(V_w2·u₂), P_shaft = ρgQH_m/η_o — manometric efficiency and shaft power (W).
  • Q ∝ N, H ∝ N², P ∝ N³ — affinity laws for one pump at changed speed.
  • N_s = N·√Q/H^(3/4) — pump specific speed; N (rpm), Q (m³/s), H (m).
  • NPSH_a = (p_atm − p_v)/(ρg) − z_s − h_fs — available NPSH (m); p_v vapour pressure (Pa), z_s suction lift (m), h_fs suction loss (m); need NPSH_a > NPSH_r.

Reciprocating pumps

  • Q = ALN/60 — theoretical discharge, single-acting (m³/s); A piston area (m²), L stroke (m), N speed (rpm). Double-acting: Q = (2A − a_r)·L·N/60.
  • C_d = Q_act/Q_th, slip = 1 − C_d — coefficient of discharge and slip.
  • P = ρgQ(h_s + h_d) — ideal power (W); h_s, h_d suction and delivery heads (m).
  • h_a = (l/g)·(A/a)·ω²·r·cosθ — acceleration head (m); l pipe length (m), a pipe area (m²), ω (rad/s), r crank radius (m), θ crank angle.
  • H_atm − h_s − h_as ≥ H_sep — no separation at the start of suction (absolute heads, m).

Centrifugal and axial compressors; turbochargers

  • w = c_p·(T₀₂ − T₀₁) — compressor work (J/kg); T₀ stagnation temperature (K), c_p ≈ 1005 J/(kg·K) for air.
  • p₀₂/p₀₁ = [1 + η_c·(T₀₂/T₀₁ − 1)]^(γ/(γ−1)) — pressure ratio; η_c isentropic (total-to-total) efficiency, γ = 1.4 for air.
  • w = ψ·σ·u₂² — centrifugal compressor work with axial entry; σ slip factor, ψ power input factor, u₂ tip speed (m/s).
  • w = λ·u·V_a·(tanβ₁ − tanβ₂) — axial stage work; λ work-done factor, V_a axial velocity (m/s), β rotor relative angles from axial.
  • η_m·ṁ_t·c_pg·(T₀₃ − T₀₄) = ṁ_c·c_p·(T₀₂ − T₀₁) — turbocharger turbine–compressor power balance.

Steam turbines: impulse and reaction staging

  • η = (h₁ − h₂)/(h₁ − h₂s) — isentropic efficiency of a turbine stage or turbine; h₁ inlet enthalpy, h₂ actual exit enthalpy, h₂s isentropic exit enthalpy at the same exit pressure (J/kg).
  • V₁ = √(2·Δh) — nozzle exit velocity (m/s) from enthalpy drop Δh (J/kg), inlet velocity neglected.
  • W = u·(V_w1 + V_w2), η_b = 2W/V₁² — impulse stage blade work (J/kg) and blade efficiency.
  • ρ_opt = cosα₁/2, η_b,max = cos²α₁ — single-row impulse stage, frictionless symmetric blades.
  • ρ_opt = cosα₁, η_b,max = 2cos²α₁/(1 + cos²α₁) — 50 % reaction (Parsons) stage.
  • R = Δh_moving/Δh_stage — degree of reaction.