Automotive Electronics and Electric Vehicles — formula sheet

Automobile Engineering · GATE ME · SI units. Drafted with Aria, checked by the AiCanCode.org team.

Lead-acid batteries: construction, rating and testing

  • Q = I × t — Q: charge (A·h; 1 A·h = 3600 C); I: current (A); t: time (h); applies at constant current.
  • E = V × Q — E: nominal energy (W·h); V: nominal voltage (V); Q: capacity (A·h); multiply W·h by 3600 for J.
  • V_t = E_oc − I × R_int — V_t: terminal voltage under load (V); E_oc: open-circuit voltage (V); I: discharge current (A); R_int: internal resistance (Ω); cranking voltage drop.
  • t = H × (C / (I × H))^k — Peukert: t: run time at current I (h); C: rated capacity (A·h) at the H-hour rate; H: rated time (h); k: Peukert exponent (about 1.1–1.3, from maker's data).

Starting system: starter motor and drives

  • P = T × ω, ω = 2π n / 60 — P: mechanical power (W); T: torque (N·m); ω: angular speed (rad/s); n: speed (rpm).
  • G = z_ring / z_pinion, n_motor = G × n_engine, T_motor = T_engine / (G × η_g) — G: gear ratio; z: teeth; η_g: gear efficiency; while the pinion is in mesh.
  • E_b = V − I × (R_a + R_f) — E_b: back emf (V); V: terminal voltage (V); I: current (A); R_a, R_f: armature and series-field resistance (Ω); stall current = V / (R_a + R_f).
  • T₂ / T₁ = (I₂ / I₁)² — series DC motor below saturation; T: torque (N·m); I: current (A).

Charging system: alternator and voltage regulator

  • f = p × n_alt / 120 — f: stator frequency (Hz); p: number of rotor poles; n_alt: alternator speed (rpm).
  • n_alt = i_p × n_engine — i_p: pulley ratio; speeds in rpm.
  • V_dc ≈ 1.35 × V_LL − 2 V_D — V_dc: mean DC output of a three-phase bridge (V); V_LL: rms line-to-line voltage (V); V_D: drop per diode (V); two diodes conduct at a time.
  • I_charge = (V_sys − E_batt) / R — I_charge: battery charging current (A); V_sys: regulated voltage (V); E_batt: battery EMF (V); R: battery plus cable resistance (Ω).

Ignition systems: battery, electronic and distributorless

  • W = ½ × L_p × I_p² — W: coil energy (J); L_p: primary inductance (H); I_p: primary current at break (A).
  • I_p(t) = (V / R) × (1 − e^(−t/τ)), τ = L_p / R — primary current build-up during dwell; V: supply (V); R: primary resistance (Ω); t: dwell time (s).
  • f_spark = n × z / 120 — sparks per second in a four-stroke engine; n: engine speed (rpm); z: cylinders.
  • t = θ / (6 × n) — t: time (s) for a shaft at n (rpm) to turn θ degrees; use distributor speed (n/2) for distributor angles.

Automotive sensors: MAP, MAF, O2, knock, crank position

  • λ = AFR_actual / AFR_stoich — λ: excess-air ratio; AFR by mass; AFR_stoich ≈ 14.7 for petrol.
  • ρ = MAP / (R × T) — ρ: intake air density (kg/m³); MAP: absolute manifold pressure (Pa); R = 287 J/(kg·K) for air; T: intake temperature (K).
  • ṁ_air = η_v × ρ × V_d × n / 120 — ṁ_air: air mass flow (kg/s); η_v: volumetric efficiency; V_d: swept volume (m³); n: speed (rpm); four-stroke speed-density.
  • f_tooth = N_t × n / 60 — f_tooth: crank-sensor tooth frequency (Hz); N_t: tooth positions per revolution; n: speed (rpm).

Actuators: injectors, solenoids and stepper motors

  • F ≈ (N × I)² × μ₀ × A / (2 × g²) — F: solenoid pull (N); N: turns; I: current (A); μ₀ = 4π × 10⁻⁷ H/m; A: pole area (m²); g: air gap (m); neglects iron reluctance.
  • m_inj = q_s × (t_pw − t_d) — m_inj: fuel per injection (kg); q_s: static flow (kg/s); t_pw: pulse width (s); t_d: dead time (s).
  • q = q_rated × √(Δp / Δp_rated) — injector flow scales with the square root of pressure difference.
  • θ_s = 360° / S, n = 60 × f_p / S — stepper: θ_s: step angle (degrees); S: steps per revolution; f_p: pulse rate (steps/s); n: speed (rpm).

Engine control unit and electronic engine management

  • m_f = m_a / (λ × AFR_stoich) — m_f, m_a: fuel and air mass per cylinder per cycle (kg); λ: target lambda.
  • t_pw = t_base × (1 + STFT + LTFT) + t_d — final pulse width (s); STFT, LTFT: fuel trims as fractions; t_d: battery-voltage dead time (s).
  • y = y₁ + (x − x₁)(y₂ − y₁) / (x₂ − x₁) — linear interpolation between map breakpoints; apply on each axis for a 2-D map.
  • V_LSB = V_ref / 2ⁿ — ADC resolution (V); V_ref: reference voltage (V); n: bits.

On-board diagnostics (OBD-II) and fault codes

  • DTC = letter + 4 characters (e.g. P0301) — P powertrain, B body, C chassis, U network; 2nd character 0 generic, 1 manufacturer-specific; for P0 codes the 3rd gives the subsystem (3 = ignition/misfire, 4 = auxiliary emission controls).
  • rpm = (256 × A + B) / 4; T_coolant = A − 40 (°C); v = A (km/h); fuel trim = (A − 128) × 100 / 128 (%) — Service 01 PID conversions; A, B: data bytes (0–255).
  • misfire rate = misfires / [(revolutions / 2) × z] × 100 — percent of firing events in a four-stroke engine with z cylinders.

In-vehicle networks: CAN, LIN and FlexRay

  • t_bit = 1 / R_b — t_bit: bit time (s); R_b: bit rate (bit/s).
  • N = 47 + 8n (standard CAN frame with inter-frame space, no stuffing); worst-case stuff bits ⌊(34 + 8n − 1) / 4⌋ — n: data bytes (0–8).
  • U = Σ (N_i / T_i) / R_b — bus load (fraction); N_i: bits per frame; T_i: period (s).
  • R_b = f_clk / (BRP × N_tq) — CAN bit rate from controller clock f_clk (Hz), prescaler BRP and time quanta per bit N_tq.

ADAS sensors and functions: radar, camera, lidar

  • d = v_w × t / 2 — d: range (m); v_w: wave speed (3 × 10⁸ m/s for radar and lidar, about 343 m/s for ultrasound); t: round-trip time (s).
  • f_D = 2 v_r / λ — f_D: Doppler shift (Hz); v_r: radial closing speed (m/s); λ: wavelength (m).
  • ΔR = c / (2B) — FMCW range resolution (m); B: chirp bandwidth (Hz).
  • TTC = d / v_rel; s_stop = v × t_lat + v² / (2a) — time to collision (s); stopping distance (m) with latency t_lat (s) and deceleration a (m/s²).

Electric vehicle architecture and drivetrain sizing

  • F_tr = m g C_rr cos θ + ½ ρ C_d A v² + m g sin θ + δ m a — tractive force (N); m: mass (kg); C_rr: rolling coefficient; ρ: air density (kg/m³); C_d: drag coefficient; A: frontal area (m²); v: speed (m/s); θ: grade angle; δ: rotational-inertia factor; a: acceleration (m/s²).
  • P_batt = F_tr × v / η_drive — battery power (W) when motoring; multiply by η when regenerating.
  • v = ω_m × r / G, T_wheel = T_m × G × η_g — r: wheel radius (m); G: overall gear ratio; T_m: motor torque (N·m).
  • Range = E_usable / e — e: energy per km (Wh/km) = P_batt (W) / v (km/h) at steady speed.

Lithium-ion cells, battery packs and thermal management

  • V_pack = N_s × V_cell, Q_pack = N_p × Q_cell, E = V_pack × Q_pack — series cells add voltage, parallel cells add capacity; E in Wh.
  • I = C_rate × Q — I: current (A); C_rate (1/h); Q: capacity (A·h).
  • R_pack = N_s × R_cell / N_p, P_loss = I² × R_pack — pack resistance (Ω) and heat generated (W).
  • ṁ = P_loss / (c_p × ΔT) — coolant flow (kg/s); c_p: coolant specific heat (J/(kg·K)); ΔT: coolant temperature rise (K).

Battery management system: SoC, SoH and cell balancing

  • SoC = SoC₀ − (1 / Q_act) × ∫ η I dt — coulomb counting; Q_act: present actual capacity (A·h or A·s); I: discharge current (A, positive); η: coulombic efficiency.
  • SoH_C = Q_act / Q_rated; SoH_R = (R_EOL − R_now) / (R_EOL − R_new) — capacity- and resistance-based state of health.
  • ΔSoC = I_offset × t / Q_act — SoC drift from a current-sensor offset I_offset (A) over t (h).
  • I_bleed = V_cell / R_bleed, t = ΔQ / I_bleed — passive balancing current (A) and time (h) to remove ΔQ (A·h).

EV traction motors: BLDC, PMSM and induction

  • n_s = 120 f / p — synchronous speed (rpm); f: electrical frequency (Hz); p: number of poles.
  • s = (n_s − n_r) / n_s; P_cu,r = s P_ag; T = P_ag / ω_s — induction motor slip, rotor copper loss (W) and torque (N·m); P_ag: air-gap power (W).
  • E = K_e ω, T = K_t I, V = E + I R — BLDC DC-equivalent model; K_e (V·s/rad) = K_t (N·m/A) in SI.
  • P_in = √3 V_L I_L cos φ, T = η P_in / ω — three-phase input power (W) and shaft torque (N·m); above base speed T = P_max / ω.

Power electronics: inverters and DC-DC converters

  • V_o = D × V_in — ideal buck converter in continuous conduction; D: duty cycle.
  • V_o = V_in / (1 − D) — ideal boost converter in continuous conduction.
  • V_LL,rms = 0.612 × m × V_dc — sinusoidal PWM inverter fundamental line voltage; m: modulation index (≤ 1); V_dc: DC-link voltage (V); space-vector PWM peak phase limit is V_dc / √3.
  • P_sw = (E_on + E_off) × f_s; η = P_out / (P_out + P_loss) — switching loss (W) from switching energies (J) and frequency (Hz).

Regenerative braking

  • E_k = ½ δ m v² — kinetic energy (J); δ: rotational-inertia factor (1 if ignored); m (kg); v (m/s).
  • E_batt = η_chain × (ΔE_k − E_road) — energy stored (J); η_chain = η_gear × η_motor × η_inverter × η_charge; E_road: drag and rolling losses during the stop (J).
  • P_brake = m × a × v; F_regen = P_regen / v — braking power (W) and the regenerative share of braking force (N) under a power limit.
  • T_m = η_g × F × r / G — motor braking torque (N·m) during regeneration.

Hybrid architectures: series, parallel and power-split

  • η_series = η_gen × η_rect × η_inv × η_mot — engine-to-motor-shaft efficiency of the series path.
  • T_shaft = T_e + T_m — parallel hybrid: engine and motor torques add on a common shaft (N·m); powers add only at the same shaft speed.
  • Z_s ω_s + Z_r ω_r = (Z_s + Z_r) ω_c — planetary (Willis) equation; Z: teeth; ω: speeds of sun, ring, carrier (signed).
  • T_r = T_c Z_r / (Z_s + Z_r), T_s = T_c Z_s / (Z_s + Z_r) — lossless split of carrier (engine) torque to ring and sun (N·m).

EV charging: AC, DC fast charging and Indian standards

  • P = V I cos φ (single-phase), P = √3 V_L I_L cos φ (three-phase), P = V I (DC) — charging power (W).
  • ΔE = E_batt × (SoC₂ − SoC₁); t = ΔE / (P × η) — energy into the battery (kWh) and charging time (h) at constant power P (kW) with efficiency η; CV taper above about 80 % adds time.
  • I_max = 0.6 × D — Mode 3 control pilot: maximum current (A) for duty cycle D (%) between 10 % and 85 %.